BFT EOS 1200 U Instrucciones De Uso Y De Instalacion página 35

Automatizaciones para puertas basculante y seccionales
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
Logic
Definition
Serial mode
(Identifies how
SERIAL MODE
board is configured
in a BFT network
connection).
Address
ADDRESS
Configuration of
command input
IC 1
IC 1.
Configuration of
command input
IC 2
IC 2.
Movement to
sw mov
limit switch
TABLE "C" – RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command
Add 2ch Key
Associates the desired key with the 2nd radio channel command. If no output is configured as 2nd Radio Channel Output, the 2nd radio chan-
add 2ch
nel controls the pedestrian opening.
Erase List
WARNING! Erases all memorized transmitters from the receiver's memory.
erase 64
Read
Checks a key of a receiver and, if memorized, returns the number of the receiver in the memory location (from 01 to 64) and number of the key
Read
(T1-T2-T3 or T4).
Read receiver code
Displays receiver code required for cloning transmitters.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter.
It remains enabled for 3 minutes from the time the W LINK transmitter is last pressed.
OFF= W LINK programming disabled.
INSTALLATION MANUAL
Cross
De-
out
fault
setting
used
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
0
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
Identifies board address from 0 to
[ ___ ]
0
(see U-LINK OPTIONAL MODULES section)
0
Input configured as Start E.
0
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
4
4
Input configured as Ped.
0
Logic not enabled
1
1
Enables movement reversal when it stops at the travel limit
Optional extras
119
in a local BFT network connection.
- 35
EOS 1200 U

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido