BFT EOS 1200 U Instrucciones De Uso Y De Instalacion página 34

Automatizaciones para puertas basculante y seccionales
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
TABLE "B" - LOGIC MENU - (logic)
Logic
Definition
Automatic Clo-
TCA
sing Time
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Block pulses
IBL OPEN
during opening
Configuration
of safety input
SAFE 1
SAFE 1.
Configuration of
AUX 3 output.
AUX 3
Fixed code
FIXED CODE
Setting the
Prot. l ev
protection level
34
- EOS 1200 U
INSTALLATION MANUAL
Cross
De-
out
fault
setting
used
0
Logic not enabled
0
1
Switches automatic closing on
Inputs configured as Start E, Start I, Ped
0
operate with 4-step logic.
0
Inputs configured as Start E, Start I, Ped op-
1
erate with 3-step logic. Pulse during closing
reverses movement.
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
0
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
0
Output configured as 2nd Radio Channel.
0
1
Output configured as SCA (gate open light). In this case, the 2nd radio channel controls partial opening.
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been
memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters
0
by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the
receiver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
0
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio
interference, if any.
Optional extras
step-by-step mov.
3 STEP
CLOSED
OPENS
DURING
CLOSING
OPEN
CLOSES
DURING
STOP + TCA STOP + TCA
OPENING
AFTER STOP
OPENS
4 STEP
OPENS
STOPS
CLOSES
OPENS

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido