Product Data Sheet
Water Filtration
System
Model NLC-250
(_
This product has been tested and certified
by NSF International
underANSI/NSF
Standard
42
for Taste, Odor and Chlorine
reduction
(Classl)
and Particulate
reduction
(Class ]) and under
Standard
53 for Cyst, Turbidity,
and Lead reduction.
Specifications:
Lead, Particulate (Class l), Cyst, Turbidity and Taste/Odor/Chlorine
reduction (Class ])
259 Gallons
(946 Liters)
Service Flow Rate 0.5 GPM (1.89 L/min) @ 60 psi
Substance
Reduction
Average
Maximum
Average
Minimum %
Average %
NSF Test
Aesthetic Effects Influent
Effluent
Effluent
Reduction
Reduction
Requirement
Chlorine
1.9 mg/L
N/A
0.04 mg/L
N/A
97.9%
minimum 75% reduction (Class ])
Particulate
610,000/mL t N/A
154/mL
N/A
99.97%
minimum 85% reduction (Class ])
Substance
Reduction
U.S. EPA
Average
Maximum
Average
Minimum % Average %
Health Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
NSF Test Requirement
Cyst
99.95%
89,250/mU 6/mL
2.3/mL
99.993%
99.997%
minimum 99.95% reduction
Turbidity
0.5 NTU
29 NTU
0.12 NTU
0.09 NTU
99.59%
99.69%
maximum effluent 1.0 NTU
Lead@pH6.5
0.015mg/L
0.16mg/U t 0.001mg/L
0.001mg/L
99.4%
99.4%
maximum effluent 0.015 mg/L
Lead@pH8.5
0.015mg/L
0.16mg/L tt 0.002mg/L
0.001mg/L
98.8%
99.4%
maximum effluent 0.015 mg/L
t Test requirement
is at least 10,000 particles/mL of AC Fine Test Dust. tt Test requirement
is 0.15 mg/L _+10%.
These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
Application
Guidelines/
Water Supply
Parameters
® NSF is a registered trademark of NSF International
Water Supply
City or Well
Water Pressure
30-120 psi (207-827 kPa)
Water Temperature
33°-100°F (0.6°-37.8°C)
• It is essential that operational, maintenance,
and filter replacement requirements
be carried
out for this product to perform as advertised.
• Change cartridge at least every 6-9 months.
Use replacement cartridge part #NLC-250 or
#4392922. Suggested retail price of $39.95
U.S.A./S49.95 Canada.
• The product is for cold water use only.
• Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system. Systems
certified for cyst reduction may be used on
disinfected water that may contain filterable
cysts.
29