Status Display
The system is designed to provide basic feedback regarding the systems current operational state. This
communication is transmitted via the LED, integrated into the control head module. The LED can be seen
flashing in a repetitive pattern representing operational state.
•
View the operation lights of the unit through the cover.
•
To operate the user interface pushbutton, remove the cover. Reassemble when finished.
LED
Green Solid
System is powered and turned ON, but not running. No faults are active. Press the button to shut the unit OFF.
Green Flashing
The pump is powered, turned ON, and running.
Green Rapid
Inlet water supply pressure is above 40 PSI. The unit remains on stand-by until the inlet pressure switch
(two blinks per second,
detects incoming water pressure below the 40 PSI limit.
then one second off)
Red Solid
The control is powered but in the OFF mode. Press the button to toggle the unit into the ON mode.
A fault has occurred. The unit will automatically attempt to restart. If an immediate restart is needed, press
Red Flashing
the button to force a reset when the fault is no longer present. If the problem persists, contact a qualified
water professional. See
MAINTENANCE
Risk of bodily injury, electric shock, or property damage.
•
Disconnect power to the unit before attempting to perform maintenance functions.
•
All maintenance functions should be performed by a qualified service professional.
Draining the System
Drain all systems, piping, and water tanks exposed to freezing weather when freezing conditions are
expected.
•
Use the drain plug on the bottom of the unit to drain the disabled (powered off) system.
•
Disconnecting the pump will not necessarily drain all other parts of the piping system. If there are
any concerns with the proper procedure or necessity of draining the suction plumbing and the sys-
tem's pressure tank, contact a water systems professional.
Description
"Troubleshooting" on page 15
for more information.
MAINTENANCE
Status Display
13