1. INTRODUCTION
This instruction manual has been drafted
in accordance with the requirements of
the Machinery Directive 2006/42/CE. The
instruction manual is an integral part of the
ground support tower to be consulted before,
during and after tower's start-up, likewise
whenever deemed necessary, respecting the
contents for each and all the parts thereof.
This is the only way to achieve the basic
objectives established in the manual's base
such as preventing accident risks and the
maximum possible optimisation for the
ground support tower features.
This manual has taken extreme care regarding
safety and accident prevention at work while
using the machine, highlighting information
of particular interest to the user.
ATTENTION: BEFORE TO USING THE
GROUND SUPPORT TOWER,
READ THIS MANUAL CAREFULLY
TRC-700
10
10
2. GENERAL DATA
2.1. Technical Data:
Name: GROUND SUPPORT TOWER
Model: TRC-700
Technical characteristics:
Maximum height: 7m.
Minimum height: 1,40m.
Maximum load: 600kg.
Minimum load: 25kg.
Material: Steel EN 10305-5 – Aluminium
EN-AW 6082-T6..
Open base area: 2,02 x 1,77m.
Closed base area: 0,995 x 0,595m.
Weight: 193kg.
Winch: 1.7000kg maximum load with
automatic load retention brake, according to
directive BGV D8, 2006/42 CE.
Truss type: Squared 29x29.
Cable: Galvanized steel under EN 12385-4.
Cable maximum load: 2.150kg, DIN 3060.
Cable torsion resistance: 1.770N/mm².
Cable diameter: 6mm.
Cable composition: 6x19+1.
Fixation of tower sections to working height
with safety pins.
Leg anchorage with safety pins.
Equipment description:
Ground support tower TRC-700 has been
designed to vertically raise structures and
lighting and sound equipment vertically to
different heights.
Tested by skilled personnel having passed all
the operating, maximum load and dimension
inspections.
7m MAX
Company: FENIX Stage, S.L.U.
Address: Avda. de los Trabajadores, 24
Horno de Alcedo - 46026 - Valencia (Spain)
2.2.- Applicable regulations
- Machinery Directive 2006/42/CE
- DIN 56921-11
- DIN 4113-2
- DIN 4112
3. GENERAL SAFETY RULES
- The lifting tower is an industrial element designed to raise loads vertically, it must NEVER
be used as a platform elevator for people.
- Only place the lifting tower on firm flat grounds checking it is in vertical position. Do not
use wedges or any strange elements to balance the hoist.
- Check legs are correctly assembled and secured by their safety pins.
- Never raise a load without first checking it is correctly supported and centred on the appro-
priate lifting tower supports, so the load only acts vertically.
- Never surpass the maximum load capacity indicated on the lifting tower characteristics label
and on this instruction manual.
- If there is a likelihood of strong wind or gusts, place the lifting tower on the ground and
secure it with the aid of straps.
- Never fix a strap over a vehicle or any other element which might move.
- Never use a ladder over the lifting tower or lean against it for any kind of work.
- Beware of any kind of projection above the lifting tower like cornices, balconies, luminous
signs, etc. It is very important to avoid the presence of cables below the lifting tower's working
height.
- Never move the lifting tower when the load is raised. It is inadvisable to make any kind of
movement, even small positioning adjustments.
- Never use the lifting tower over any mobile surface or vehicle.
- Before using the lifting tower, check the cable's state, which must not present any broken
threads or compression. NEVER use defective cables and change cable if in doubt. Only use
steel cable as described on this manual.
- Fix the lever when the load is raised.
- Minimum load for braking function without problems is 25kg. Brake will not function
without this minimum load.
- Neither grease nor lubricate the winch brake mechanism. Braking disks were greased with a
special heat and pressure resistant grease. No other products must be used to prevent negative
influence on brake functioning.
- All sections of the lifting tower must be lowered to transport it.