Descargar Imprimir esta página

Metabo Basic 270 Manual De Instrucciones Original página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
ENGLISH
3.
Store machine in such way that it
cannot be started by unauthorized
persons.
A
Caution!
Do not store machine unpro-
tected outdoors or in damp environ-
ment.
6. Trouble Shooting
Danger!
A
Prior to all servicing:
− Switch Off.
− Unplug.
− Wait until the compressor has
come to a complete stop.
− Ensure the compressor and all air
tools and accessories connected
to it are relieved from pressure.
After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts
remain
on
machine.
Compressor does not run:
No mains voltage.
9. Technical Specifications
Suction capacity
Free air delivery (volume flow rate)
Filling rate
Working pressure (compression end pressure)
Pressure vessel volume
No. of air outlets
Pump model
No. of cylinders
Motor speed
Motor capacity
Supply voltage (50 Hz)
Rated current
Fuse protection min.
Degree of protection
Max. overall cable length when using extension cables:
2
– at 3 x 1.0 mm
lead cross section
2
– at 3 x 1.5 mm
lead cross section
2
– at 3 x 2.5 mm
lead cross section
Oil grade (pump)
Required oil quantity (pump)
Dimensions length x width x height
Weight
Sound pressure level at 1 m max.
10
− Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.
Compressor
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
Motor has overheated, caused by
insufficient cooling (cooling fins cov-
ered).
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
Check valve leaky.
− Have check valve serviced by
qualified service centre.
or
in
the
Air tool is not supplied with sufficient
pressure.
Pressure regulator not opened wide
enough.
was
stopped
by
l/min
l/min
l/min
bar
l
-1
min
W
V
A
A
m
m
m
l
mm
kg
dB (A)
− Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
Danger!
A
Repairs to power tools must be
carried out by qualified electricians
only!
Power tools in need of repair can be sent
to one of the adresses listed on the sec-
ond-last page.
Please attach a description of the fault to
the power tool.
8. Environmental Protection
The machine's packaging can be 100 %
recycled.
Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
250
125
150
8
50
2
GM 243
1
2850
1.5
230
6.5
10 (time-lag)
IP 20
10
25
25
SAE 5 W 50 synthetic
approx. 0.220
905 x 410 x 690
35
86 ± 3