en
3 Technical specifications
Model
Sound power level, indoors (L
Storage volume (V)
Mixed water at 40°C (V40)
Heat input (HP)
Absorbed electrical power (HP)
COP in accordance with the EN16147 standard
Maximum air flow rate
Electrical resistor output
Operating pressure
Power supply voltage
Circuit breaker
Heating time (10-54°C)
Pes
(5)
Refrigerant fluid R-134a
R-134a regfrigerant
(6)
Weight of the tank (empty)
Protection of the thermodynamic water heater
Acoustic pressure
(7)
Minimum water inlet pressure
Maximum water inlet pressure
(1) Value obtained with an air temperature of 7°C when heating from 10°C to 54°C.
(2) Value obtained with an air temperature of 15°C when heating from 10°C to 54°C.
(3) Value obtained with an air temperature of 7°C and a water inlet temperature of 10°C according to EN16147 based on LCIE Specifica
tions No. 103-15/B: 2011.
(4) Value obtained with an air temperature of 15°C and a water inlet temperature of 10°C according to EN16147 based on LCIE Specifica
tions No. 103-15/B: 2011.
(5) Absorbed electrical power at stabilised rate.
(6) Quantity of refrigerant calculated in tonnes of CO
(7) Measured at a distance of 2 metres.
188
ETWH
)
WA
equivalent.
2
Unit
ETWH 180 E
dB
60
Litre
180.0
Litre
207
W
1000
/ 1500
(1)
W
400
/ 460
(1)
(2)
2.38
/ 2.88
(3)
(4)
350
3
m
h
W
1550
MPa (bar)
0.8 (8)
V
230
A
16
hours
8h39
/ 6h02
(3)
W
37.0
/ 25.0
(3)
(4)
kg
0.8
tCO
e
1.14
2
kg
102
IP21
dB (A)
46.2
MPa (bar)
0.15 (1.5)
MPa (bar)
0.65 (6.5)
ETWH 230 E
60
230.0
318
1000
/ 1500
(2)
(1)
(2)
400
/ 460
(1)
(2)
2.51
/ 3.02
(3)
(4)
350
1550
0.8 (8)
230
16
11h50
/ 7h54
(4)
(3)
46.9
/ 33.6
(3)
(4)
0.8
1.14
116
IP21
46.2
0.15 (1.5)
0.65 (6.5)
7659610 - v04 - 27072020
(4)