1 Thermodynamic water heater
7659610 - v04 - 27072020
6.3.2
Example of hydraulic connection in HYBRID Mode
2
50
100
°C
20
120
bar
4
0
ON
OFF
A
3
1
2
U
T
0
230V
50Hz
6.3.3
Hydraulic connection between the thermodynamic water
heater and an instant boiler
MW-5000495-1
2 Instant boiler
Connecting the condensate discharge pipe
1. Insert the condensate collector hose (Ø 9 mm) into the discharge
opening.
Caution
Do not block the condensate discharge pipe.
Connect the condensate discharge pipe in accordance with
prevailing local standards.
Safety valve or safety unit
Caution
Germany: In accordance with the safety regulations, a safety
unit calibrated to 0.6 MPa (6 bar) must be fitted on the domestic
cold water inlet on the domestic hot water tank.
Belgium: In accordance with the safety regulations, a safety unit
calibrated to 0.7 MPa (7 bar), and approved by Belgaqua, must
be fitted on the domestic cold water inlet on the domestic hot
water tank.
Other countries: In accordance with the safety regulations, a
safety unit calibrated to 0.7 MPa (7 bar) must be fitted on the
domestic cold water inlet on the domestic hot water tank.
We recommend NF-marked hydraulic diaphragm safety units.
Integrate the safety valve in the cold water circuit.
6 Installation
1
en
ETWH
203