5. Others
5.1 Maintenance
Check whether the gate operates normally every month.
For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required.
Before installation and operation of the gate opener, please read all instructions carefully.
Our company reverses the right to change the instruction without prior notice.
5.2 Troubleshooting
The gate cannot open
or close normally, and
LED does not light.
The gate can open but
cannot close.
Remote control doesn't
work.
Press OPEN, CLOSE
button, the gate is not
moving, motor has
noise.
Not stop at the limit
position when opening /
closing.
KEEP WORKiNG
Keep Working
Problems
1. The power is off.
2. Fuse is burned.
3. Control board power wiring with
problem.
1. Photocell wiring with problem.
2. Photocell mounting with
problem.
3. Photocell is blocked by objects.
1. Battery level of the remote
control is low.
2. Remote control learning is not
completed.
1. Capacitor is broken.
2. Capacitor is poor connected.
3. Gate moving is not smoothly.
1. The limit direction is wrong.
2. The mounting of magnetic limit
switch with problem.
Possible Reasons
14
Solutions
1. Switch on the power supply.
2. Check the fuse (code FU),
change the fuse if burnt.
3. Re wiring according to
instructions.
1. If not connect photocell or if
connect infrared sensor,
please learn travel again to
remake.
2. Make sure that the photocell
mounting position can be
mutually aligned.
1. Change the remote control
battery.
2. Re-conduct remote control
learning.
1. Change capacitor.
2. Check the capacitor wiring.
3. According to the actual
situation to adjust the motor or
the gate.
1. Check whether the limit
switch wiring is consistent with
the actual direction of
operation. Please learn travel
again to remake.
2. Check whether the distance
between magnetic limit switch
and motor, and the height of
the magnetic limit switch can
reach up the mounting
requirement.
M C
1 2