INSTALLATION
Reversing the Access Door
Flav-R-Savor Humidified Holding and Display Cabinet access
door(s) may be hinged on either the left or right side for
convenience. Use the following procedure to reverse the
access door.
NOTE: For models equipped with a rotating rack motor (FSD-1,
FSDT-1, FSD-2, and FSDT-2), the "Relocating the
Proximity Switch" procedure in this section must be
performed after reversing the access door(s).
1. Remove the top hinge pin screw holding the door to the
hinge.
2. Tip the door assembly forward (away from cabinet) and lift
gently to clear the bottom hinge assembly. Remove the
nylon washer(s).
3. Reinstall the top hinge pin screw that was removed in step 1.
4. Remove the screws holding the hinges to the cabinet.
Hinge Assembly
Reversing the access Door
5. Remove the screws from the striker plates on the non-hinge
side of the cabinet.
6. Install the striker plates on the opposite side of the cabinet
where the hinges were previously mounted.
7. Install the hinges on the opposite side of the cabinet where
the striker plates were previously mounted using the original
hinge mounting screws.
8. Carefully rotate the door 180°.
9. Remove the hinge pin screw from the end that is now the
top.
10. Carefully place the door assembly with the nylon washer(s)
into the bottom hinge.
11. Tip/tilt the door assembly towards the cabinet and align the
door top with the hinge. Reinstall the top door hinge pin
screw through the hinge and into the door top.
Striker Plate and
Hardware
Top Hinge
Pin Screw
8
Door Rotated 180°
Bottom Hinge Pin Screw and
Nylon Washer(s)