Descargar Imprimir esta página

STEINEL professional Serie Manual Del Usuario página 17

Ocultar thumbs Ver también para professional Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
b) Connect service lead
The service supply lead
to the light is also a 2 to
3-core cable. Connect the
light's current-carrying
conductor to the terminal
marked L'. The service lead
neutral conductor must be
connected to the terminal
marked N together with the
6. Installation using corner wall mount
7. Functions
Once you have connected
the unit to the mains power
supply, closed the housing
and fitted the lens, you are
10 sec.
15. min.
2
2,000 lux
mains lead neutral conductor.
Connect the protective-
earth conductor to the
earth contact (
).
7. Screw on housing
and close again.
8. Fit lens (set reach to
either 5 m or 12 m max),
see 'Reach setting' section.
9. Select time
5
and light
ready to put the system
into operation. Two setting
controls are concealed
behind the front cover
Switch­off delay
(time setting)
The chosen light ON time
can be varied continuously
from approx. 10 sec. to a
maximum of 15 min. Turning
the adjustment screw fully
anti-clockwise selects the
shortest time of approx.
5 sec., turning the adjust-
Twilight setting
(response threshold)
The chosen detector
response threshold can be
adjusted continuously from
approx. 2 lux to 2,000 lux.
Turning the adjustment
screw fully anti-clockwise
selects daylight operation
at approx. 2,000 lux.
– 17 –
threshold setting
'Functions' section).
10. Locate front cover
and fit security screw
protect cover from unau-
thorised removal.
Important: Reversing the
connections may result in
damage to the unit.
With the corner wall brack-
ets, the IS 2180 ECO can be
conveniently mounted on
inside and outside corners.
Use the corner wall bracket
as a drilling template when
drilling the holes. In this
way you place the drill hole
at the right angle and the
corner wall bracket can
be mounted without any
problems. The corner wall
brackets (EAN 40071085131
black / 40071085148 white)
are available as accessories.
Important: Only carry out
time and light threshold
settings with the lens fitted.
2
.
ment screw fully clockwise
the longest time of approx.
15 min. The shortest time
setting is recommended
for setting the detection
zone and performing the
walk test.
Turning the adjustment
screw fully clockwise
selects twilight operation
at approx. 2 lux. The
adjustment screw must be
turned fully anti-clockwise
for setting the detection
zone and performing the
walk test in daylight.
4
(see
GB
2
1
to

Publicidad

loading