11. Parallel-connected configurations
When using several detectors,
they must be connected to the
same phase!
14.1 Master / master
A parallel-connected configu-
ration also permits the use of
several masters. In this case,
each master operates the lighting
group in accordance with the
14.2 Master / slave
The master / slave configuration
permits detection of movement in
large-type rooms or spaces (load
connected = master, no load =
slave). The level of brightness
prevailing in the room is only eval-
14.3
Two detectors linked with
an external stairwell lighting timer
14.4
Detector as stairwell light-
ing timer
14.5
DIM detector
*
This external button cable is not
intended to serve as a neutral
conductor connection for loads
(see page 6 / 7).
12. Remote control
Using the remote control (op-
tional), functions can be conven-
iently activated from the floor.
As many as 10 sensors can be
connected in parallel.
level of brightness it measures.
Delay times and light-level thresh-
olds are selected at each master
as required. The switched load is
spread among the individual mas-
uated at the master. The slaves
report movements detected to
the master. Lighting or HVAC
is switched ON and OFF by the
master only.
Old building / building
modernisation
Note: The pulse mode cannot
be overridden by the remote
control. Switch pulse mode OFF
manually.
- 28 -
ters. Presence is still detected
collectively by all detectors. The
presence output can be picked
off from any master.
External light source activated
by button. No twilight mode, day
mode only.
Presence Control remote control
unit: EAN no: 4007841 559410