TROUBLESHOOTING
Technical assistance before seeking further assistance from a qualified professional:
The heater does not turn on:
- Check the gas cylinder to make sure the gas level is full and not empty.
- Check that the regulator is correctly connected and that the cylinder valve is
open.
- Check that all instructions have been followed correctly.
If this happens after you have changed the cylinder, it may be due to:
Air in the cylinder:
hold down the control knob for a longer period of time
until the pilot and main burner light. Change setting to 3 - HIGH.
The cylinder may have been excessively cold.
Allow the cylinder to come to room temperature before attempting to light the heater.
The heater turns itself off:
If the heater goes out in continuous operation, repeat the operation, clearly following the
instructions and check that the gas cylinder still contains gas.
If it goes off shortly after 30 minutes, it indicates that it is operating in a poorly ventilated area.
Open a window or door to ventilate the area and turn the power back on.
Avoid hitting the heater while it is running. Do not move the heater while it is in operation.
-The power switch can be activated and turn off the heater.
TECHNICAL DATA:
Product Dimensions: 420*410(290)*730mm(W*D*H)
Device category: I3B
Pressure: Butane at 28-30 mbar
Heater input: 1.5 kW (minimum), 2.8 kW (medium), 4.20 kW (maximum)
Gas consumption: 110 g/h (minimum), 207 g/h (medium), 305 g/h (maximum)
Injector Size: 0.59mm
Ignition system: piezo ignition
Recommended type of cylinder (bottle): Up to 7.0 kg BUTANE – a maximum of 32 cm in
diameter x 55 cm (height).
EN449:2002+A1:2007