FAULT
The motor stops suddenly
The pressure adjustment valve trips continuo-
usly during work
The adjustment valve trips when the spray
gun is closed
The machine doesn't intake additives
English
REASONS
rheating
Water nozzle partially obstructed
Water filter dirty
Leaks in the intake circuit
Leak in the spray gun
Air in the water circuit
High pressure hose broken
Faulty adjustment valve
Additives tank empty
The additives valve is obstructed
The intake hoses and/or the filter are dirty.
- 15 -
REMEDIES
switch and leave to cool for a few minutes.
Clean the water nozzle
Clean the water filter
Contact the technical service centre
Clean the inside of the spray gun removing
any deposits or impurities.
Contact the technical service centre
Repeat the operations shown for
"High pressure hose vibrates"
Replace the high pressure hose
Contact the technical service centre
Make sure the additive liquid is not finished, if
so, fill up the tank. Before using the machine
with additives, wait for all the air that has
entered the circuits to be expelled.
Check , clean and replace the valve if neces-
sary.
Check and clean.