6. ELECTRICAL CONNECTIONS
A. Connect disposer to appropriate household current
only.
WARNING:
A RISK OF ELECTRIC SHOCK. CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICEMAN IF YOU ARE IN
DOUBT AS TO WHETHER THE APPLIANCE IS PROPERLY GROUNDED. DO NOT MODIFY THE PLUG PROVIDED
WITH THE APPLIANCE IF IT WILL NOT FIT THE OUTLET. HAVE A PROPER OUTLET INSTALLED BY A
QUALIFIED ELECTRICIAN.
GROUNDING INSTRUCTIONS
FOR WASTE DISPOSERS EQUIPPED WITH A
GROUNDED PLUG-IN POWER CORD.
B. This appliance must be grounded. In the event of a
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock. This appliance is equipped with
a cord having an equipment-grounding conductor
7. OPERATING INSTRUCTIONS
The Anti-Jam Swivel Impellers make a clicking
sound as they initially swing into place. This
indicates normal operation.
A. Remove sink stopper. Turn on a medium flow of cold
water.
B. Turn switch to ON position; your motor is turning at
full speed and ready to use.
C. Scrape in food waste. Down the drain go table scraps,
peelings, rinds, seeds, pits, small bones and coffee
grounds. To speed up food waste disposal, cut or
break up large bones, rinds and cobs. Large bones
and fibrous waste require considerable grinding time
AIR SWITCH OPERATED
Disposer Air Switch Assembly
The Actuator which consists of:
1. Actuator Button
2. Actuator Nut
3. Actuator Outlet (Threaded portion)
The Air Switch Sensor Enclosure which is installed into
the disposer. Only the air tube nozzle is visible from the
outside of the disposer.
Air Tube Assembly which consists of:
4. Air Tube-Clear or black
5. Air Tube Nut/Sensor Inlet
Installation And Operating Instructions
A. If a hole does not already exist - drill a hole of 35mm
to 40mm into the sink or countertop where the Actuator
Button (#1) is to be placed.
B. Insert, from the top, the Actuator Outlet through the
drilled hole.
C. Thread the Actuator Nut (#2) onto the Actuator Outlet
(#3) and tighten firmly by hand.
D. Firmly connect Air Tube (#4): one side to Actuator
IMPROPER CONNECTION OF THE EQUIPMENT - GROUNDING CONDUCTOR CAN RESULT IN
The receptacle to which this appliance is
connected must be controlled by a switch.
and a grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and
grounded in accordance with all local codes and
ordinances. If the supply cord is damaged it must be
replaced by the manufacturer, its service agent or
similarly qualified person in order to avoid a hazard.
and are more easily thrown away with other trash. Do
not be alarmed that the disposer slows down while
grinding. The disposer is actually increasing torque
(grinding power) and is operating under normal
conditions.
D. Before turning disposer off, let water and disposer run
for approximately 15 seconds after shredding or
grinding stops. This assures that all waste is thoroughly
flushed through trap and drain.
E. It is not recommended to use hot water while running
disposer. Cold water will keep waste and fats solid so
disposer can flush away particles.
Outlet (#3) and one side to Sensor Inlet (#5)
E. Plug Disposer Power Cord into main electrical service.
F. To turn on disposer, press Actuator Button (#1). To turn
off, press Actuator Button again.
1.
2.
3.
4.
7