6. Generator usage
WARNING: Be sure to connect the ground connection to an independent
ground rod. Grounding protects the user in case of accidental discharge. Failure to
make this connection exposes the user to the risk of serious injury or death in the
event of a shock. If you have doubts, ask your electrician.
WARNING: Never connect the 230V output of the equipment to a building or
house (not even during a power outage). The return of the main network would
clash with the generator's power and cause serious damage to the equipment or
even a fire.
WARNING: Do not connect in parallel with the generators, both will be
damaged and will be a fire hazard.
NOTE: Do not connect an extension to the exhaust.
NOTE: If a cable extension is needed, make sure you use a good quality
rubber extension and appropriate section:
60m cable length: use a 2mm
100m cable length use a 2.5mm
NOTE: Devices that use an engine such as compressors, water pumps,
saws, radials, etc. require up to 3 times more power for start-up. For example, a
500 W water pump would need a 1500 W generator for start-up. Verify that
charges upon connection do not exceed the maximum power of the group
according to this indication.