Operating instructions
1.  Press 
 button once to start operation, the power indicator will be on. Press it again to stop operation.
2.  Press 
 button to program the time when the unit turns on and turns off.
Press 
 button to set Automatically Off time while the unit is running, the timer icon (2) light is on.
Press 
 button to set Automatically On time while the unit is in standby, the timer icon (2) light is on.
The time can be adjusted within a range of 1 hour to 24 hours. Press the temp up (+) or temp down 
(-) button to increase or decrease the time 1 hour by pressing once.
If you want to cancel the timer programming, press the button to adjust the time at 0.
The programmed time will be canceled when compressor switches on/off manually.
The programmed time remains unchanged if the machine stops due to water full or during defrosting.
3.  Press 
 speed button to to select wind speed. 
4.  Press 
 button to start or stop the Laundry function.
5.  Press 
or
 button to set the desired humidity level in the room, which can at 5% intervals or "CO" 
for continuous working. or "CO" be set from 30% to 90%.
After a period of working,when environment humidity is lower than the selected humidity by 2%, 
compressor will stop ; When environment humidity is equel to or higher than the selected humidity 
by 3%, compressor will restart once 3-minutes compressor protection time over.When setting the 
humidity to " CO ", the compressor will run continuously .
Water full light
When the water tank is full,removed or incorrectly inserted the unit will stop dehumiditfying,the tank full light 
will illiminate and the unit will beep. Empty the tank and reinsert it correctly to resume operation.
Humidistat control and fan/compressor operation
When the humidity of the room is 2% lower than the desired humidity, the compressor will turn off 
automatically but the fan will continue to operate to ensure that the air within the room is not stale. The unit 
will use only a minimal amount of energy in fan mode.
When the humidity of the room is equal to or higher than the desired humidity, the compressor will restart 
after 3 minutes delay to protect the compressor.
Compressor light (Power LED)
When the compressor is running, it is ON for a long time; When the compressor stops running, it flashes.