7
DIMENSIONS OF WEAR FOR DIAMETERS AND LENGTHS OF
THE POKERS
MODELO
A.
B.
C.
D.
8 PERIODIC MANTENANCE OF MOTOR
1. Only an expert shall work on the electrical parts.
2. Make sure that the plug is disconnected during repairs.
3. In all maintenance operations, original parts will be used.
4. A periodic lubrication of the motor bearings is not necessary.
5. Every 50 hours carbon brushes should be inspected. They should be changed if effective length is under
8 mm. Change the brushes:
a) With a screwdriver remove the side cap of the housing, introducing the screwdriver between the cap and
the housing and lever it.
b)We find the brush retainer 103652, this is a threaded part, with a screwdriver remove it, we can see the
brush 103653 or 103654(115 V), turn the motor and the brush goes out or introduce a thin tool to remove it.
c) To assemble introduce the new brush and thread the retainer and finally close the housing with the cap.
d) After change brushes, running motor at least 5 minutes without shaft neither poker.
6. Clean the ventilation vents in the front and back part of the motor periodically to avoid overheating.
7. Check that the filter is situated in the air intake, under the switch. If it is dirt, change it. To
press with both hands on the rear grating in the place where it says "PRESS", take out the grating (96207)
and the filter (96203) and replace with another new one. Then mount the grating, firstly inserting the
bottom into its guide and then the upper part whilst pressing the "PRESS" indications.
8. After maintenance job and service, all safety devices should be assembled correctly.
9. Tighten the bolts.
10. Every 12 months or more frequently, depending on the usage conditions, it's recommended a
inspection be done by an authorized dealer.
11. Clean the filter on a regular basis or replace if necessary.
DINGO MOTOR - FLEXIBLE SHAFT AND POKERS
TDX1m, TDX1-5m, TDX2m, TDX3m, TDX4m, TDX5m, TDX6m
DIAMETRO
(mm)
AX 25
23,5 (25)
30,5 (32)
AX 32
AX 40
38,5 (40)
AX 48
45,5 (48)
55,5 (58)
AX 58
The minimum dimensions are bold printed.
The dimensions into brackets are the original dimensions.
Replace the housing when reach the minimum diameter.
Replace the tip when reach the minimum length.
DINGO - AX25, AX32, AX40, AX48, AX58
LONGITUD
(mm)
310 (320)
360 (366)
330 (335)
355 (360)
339 (344)
en
do this,
9