22 INSTALLATION
NOTE
• The hookup line cannot be white, plastic tubing.
Licensed plumbers must use only copper tubing
(NDA tubing #49595 or #49599) or Cross Link
Polyethylene (PEX) tubing.
4
Fasten the shutoff valve.
• Fasten the shutoff valve to the cold water
pipe with the pipe clamp.
NOTE
• Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed
plumber.
Pipe Clamp
a
Saddle-Type Shutoff Valve
b
Vertical Cold Water Pipe
c
5
Tighten the pipe clamp.
• Tighten the clamp screws until the sealing
washer begins to swell.
NOTE
• Do not over tighten clamp or you may crush the
tubing.
Pipe Clamp
a
Inlet End
b
Clamp Screw
c
Washer
d
6
Route the tubing.
• Route the tubing between the cold water
line and the refrigerator. Route the tubing
through a hole drilled in the wall or floor
(behind the refrigerator or adjacent base
cabinet) as close to the wall as possible.
NOTE
• Be sure there is sufficient extra tubing (about 8
ft. coiled into three turns of about 10 in.
diameter) to allow the refrigerator to move out
from the wall after installation.
7
Connect the tubing to the valve.
• Place the compression nut and ferrule
(sleeve) for copper tubing onto the end of
the tubing and connect it to the shutoff
valve. Make sure the tubing is fully inserted
into the valve. Tighten the compression nut
securely.
Saddle-Type Shutoff Valve
a
Compression Nut
b
Packing Nut
c