Troubleshooting

Faults - causes and remedies

Fault
The motor does not start
after pressing the ON/
OFF switch or stops during
operation.
The automatic circuit
breaker in the electrical
distribution board trips
The magnetic clamp does
not function.
The lubrication system
does not function.
NOTE
If you cannot resolve the problem with the steps described above, please contact
After-Sales Service.
CS Unitec, Inc., 22 Harbor Ave., Norwalk, CT 06850 • Toll-free: 800-700-5919 • Ph: 203-853-9522
Fax: 203-853-9921 • Email: info@csunitec.com • Website: www.csunitec.com
MAB 825/845
Possible cause
Plug not inserted into socket.
Automatic circuit breaker
tripped.
The magnetic clamp is not
switched on.
The internal safety switch
has switched off the machine
due to overheating.
Direction of rotation not
selected.
The torque cut-out has
tripped.
Too many appliances con-
nected to the same power
circuit.
Machine is defective.
Magnet not switched on.
The surface is not magnetic.
No lubricant available.
Lubricant tap closed.
Connecting nipple clogged.
Troubleshooting
Remedy
Insert plug.
Switch on the automatic circuit
breaker again.
Switch on the magnetic clamp.
Allow the machine to cool
down.
Preselect direction of rotation.
Switch the machine off and on
again.
Reduce the number of appli-
ances on the power circuit.
Contact After-sales Service.
Switch on magnet.
Use a suitable base.
Top up the lubricant.
Open the lubricant tap.
Clean tank and nipple.