SAFE T Y N OT ES
W A R N I N G : To avoid the risk of product
failure, propert y damage, and personal
injury, do the following:
This product should be installed by a licensed pro-
fessional plumber.
This product is for use with drinking water only.
THIS TUB FILLER MUST NOT BE USED AS A GRAB
BAR. If a grab bar is required, install one separately.
Refer to the Cleaning Recommendations on page
19 when selecting a cleaning agent for this
product. Do not use cleaning products containing
chlorine bleach, lye, hydrochloric acid, formic acid,
acetic acid, or abrasives.
Failure to follow these instructions may result in prod-
uct failure and property damage, and may void the
warranty.
INSTALLATION CONSIDERATIONS
⁄ Read over these instructions thoroughly before beginning
installation. Make sure that you have all tools and sup-
plies needed to complete the installation.
⁄ This trim is for use with rough 10452181 (not included).
The rough must be installed and the finished floor surface
completed and made watertight.
⁄ This unit is not anti-scald. If required by local plumbing
code, install an approved water temperature limiting
device conforming to ASSE 1070 (not available from
Hansgrohe).
⁄ Protection against backflow is provided by check valve
and an automatically resetting diverter.
⁄ This showerhead is for use with an automatically com-
pensating valve rated at 1.3 GPM (4.9 L/min) or less.
⁄ Keep this booklet and the receipt (or other proof of date
and place of purchase) for this product in a safe place.
The receipt is required should it be necessary to request
warranty parts.
2
E N G L I S H
TEC HNIC AL INFORMATION
Water pressure
Recommended
Maximum
Hot water temp.
Recommended
Maximum
Flow rate
spout
handshower
* Please know and follow all applicable local plumbing
codes when setting the temperature on the water heater.
15 - 75 PSI (0.1 - 0.5 MPa)
120°-140° F (48° - 60° C)*
4.8 GPM (18.2 L/min)@ 44 PSI
max. 1.75 GPM (6.6 L/min)
INSTALLATION HINT: When you see this
symbol, do not discard the part or parts in-
dicated. Keep it in a safe place in case it is
needed to repair the product.
145 PSI (1 MPa)
158°F (70° C)*