D. Operation panel instruction
3. Parameter Setting:
Press "MODE" button for 5 seconds; enter the Parameter setting status, the main
parameter code as below sheet:
Type
Code
F8
F9
F11
F12
F13
F14
Temperature
F15
Control
F16
F17
F18
F19
F21
F28
Compressor
F29
F31
F32
Defrost
F33
F34
F50
F51
F52
F54
Alarm
F55
F56
F57
F58
F59
F60
Function
Setting
F61
F62
Parameter Name
PV switch connected
temperature setting
PV switch disconnected
temperature setting
Setting temperature
Difference in Temp.
Determine Heat pump
stop ambient temp.
Highest temp. for heat pump
Turn on or off electric
heater mode
Ambient temp. for start
electric heating
Turn on or off electric heater for
sterilization function
Sterilization cycle
Water thermal sensor
temp. amendment
Compressor start delay
Econ mode turn on or
off electric heater
Heat pumps working or not
in heater mode
Defrost start temp.
Defrost finish temp.
Defrost start time
Max. defrost time
Low pressure alarm mode
Auto resume times of
low pressure alarm
Reset time of external alarm
auto resume times
Electric heater
overheat protection
Overheat resume time
Alarm resume time
Exhaust temp.
protection mode
Exhaust protect temp.
Exhaust temp. protection
Return difference
Condenser water
hole blocked alarm
Memory status when power off
PV switch ON/OFF
Factory Setting
Setting Range
5-70
5-70
5-70
1 - 30
-10 – 5
40 – 60
0 - 1
-10 - 20
0-1
1-990
336
-5 – 5
0 – 10
0 - 1
0 - 1
-20 – 20
0 – 50
1 – 999
Off, 1 – 99
0 - 2
0 – 10
0 – 999
0 - 2
0-10
0-999
0 – 2
50 – 125
110
1 – 30
0-2
Yes/No
Yes
0-1
9
Unit
Remark
60
°C
50
°C
55
°C
5
°C
-7
°C
75
°C
1
-
0
°C
1
hour
°C
0
minute
3
1
1
-2
°C
25
°C
30
minute
5
minute
2
-
3
time
60
minute
2
-
3
-
60
°C
1
-
°C
10
°C
-
2
-
-
1
V.1