CLOSING LEAF DELAY TIME
-
+
0s - 18s
DWELL TIME (If Dip-Switch 3=ON)
0s - 120s
-
+
OPERATING TIME
-
+
2s - 100s
Pre-flashing Dip-Switch 4=ON: Once the control pulse has been given the
flashing light switches on and the operator starts 3 seconds later.
FUNCTIONS
Automatic cycle: when an open pulse is given, the leaves open, they stop in dwell for the time
set on the timer, after which they close automatically.
Semi-automatic cycle: when an open pulse is given, the leaves open. To close the leaves, give
the close pulse.
Pedestrian opening of a completely closed gate leaf is obtained giving an Open command, with
Dip-Switch no. 6=ON, to terminals 3-4:
- a first opening command opens the Motor 1 leaf
- with a second command to terminals 3 and 4, the second leaf also opens.
The transmitter is always enabled for both leaves with Radio Contact 7-8.
The function "Pedestrian Opening" is not in service during the first operation cycle,
after a power failure.
Function (Dip-Switch no. 7=ON) t
Function (Dip-Switch no. 7=ON)that facilitates disengagement of the electric lock when the gate
is completely closed, even in Pedestrian Opening mode: with the gate leaves closed, before
is completely closed, even in Pedestrian Opening mode: with the gate leaves closed, before
opening they are pushed to close for 2 seconds.
opening they are pushed to close for 2 seconds.
Dip-Switch no.5=ON At each pulse on the radio contact the gate performs open-stop-close-stop
CLOCK: The Elpro 13 exp Programmer makes it possible to connect a normal clock for opening-closing
Wiring: connect in parallel the NO contact of the Clock with terminal no. 4 OPEN and no. 3 COMMON, activating automatic re-closing
with the Dip-Switch no. 3=ON and setting the dwell time on the trimmer
Operation: programme the opening time on the clock, at the time set the gate will open and remain open (the flashing light switches
off and the indicator light gives the signal with two quick flashes followed by a longer dwell) and will not accept any further command
(including radio commands) until the time set on the clock has elapsed, at the end of which, following the dwell time, automatic
reclosure will take place.
-
+
DWELL TIME
0s - 120s
1643
Drwg. No.
8
8
13
exp
230V SINGLE-PHASE PROGRAMMER FOR SWING GATE OPERATORS
16 17
18
19 20
16 17
M1
ON = Closes in Automatic mode
OFF = Does not close in Automatic mode
3
Semi-automatic function
21
22 23
24
25
18
19 20
21
M2
22 23
4
24 25
-
+
DWELL TIME
0s - 120s
ON= Single-leaf pedestrian service
OFF= Normal service
6
ON: Stroke reversing pulse function enabled
when opening from closed gate
OFF: Stroke reversing pulse deactivated
7
ON: Step-by-step function enabled
OFF: Step-by-step function deactivated
5
ON: Eliminates the Leaf delay when opening.
The motors start together
OFF: Leaf delay when opening enabled
8
ON = Closes in Automatic mode
OFF = Does not close in Automatic mode
3
Semi-automatic function
ON: Pre-flashing
OFF: Without pre-flashing
230 VOLT
ON = Closes in Automatic mode
OFF = Does not close in Automatic mode
3
Semi-automatic function
M1
3
4
External clock
NO