6. ELECTRIC WORK
HEATING MODEL:
(220V)
7.
OPERATION
7.1. HEATING MODEL:
7.1.1. Controlled by remote controller
a. Press "ON/OFF" button to turn ON the unit. Main receiver receives the signal with the sound of "beep" to start
working with the green light in cool mode at high speed "H". Press "ON/OFF" button again to turn OFF.
b. When the unit is working at the above a. situation, press "COOL" button in the Remote controller, receiver
receives the signal with the sound of "beep" and switch high speed to low speed "L". Meanwhile there is a
green light display in the receiver. Press "COOL" button again, the unit will switch low speed to high speed. So
when the unit is working at cool mode, press "COOL" button can switch air curtain working under the cycle of
Low or High speed.
c. When the unit is working at the above b. situation, press "HEAT" in the remote controller, receiver receives the
signal with the sound of "beep" and switch cool mode to heating mode at low power. Meanwhile there is a
Red light display in the receiver. Press "HEAT" button again, the unit will switch low power to middle power.
Meanwhile there is TWO Red lights display in the receiver. Press "HEAT" button again, the unit will switch
middle power to high power. Meanwhile there is THREE Red lights display in the receiver. Press "HEAT" button
again, the unit will switch heating mode to cool mode and the red lights display change to green light in the
receiver. So HEAT function, when the unit is working at cool mode, press "HEAT" button can switch air curtain
working under the cycle of heating low power, heating middle power, heating high power and then cool mode.
d. When the unit works at cool mode, press "ON/OFF" button to turn OFF the unit.
e. When the unit works at heating mode, press "ON/OFF" button, the unit will switch to cool mode at high speed,
the indication light turns to green flicker light. The unit will continue to work in cool mode for 30 seconds and
then stop. (This is to ensure the heater is been cooled down and has 30 seconds delay stop).
7.1.2. Controlled by the control panel in the unit is the same function as 7.1.1.
7.1.3. Overheat protection:
When the air curtain works at heating mode, there is overheat protection. When the heater temperature is
overheating, heating mode will stop and switch to cool mode automatic, at the same time the indication
light change to green light. When the temperature drop down to a certain temperature, if want the unit to
work at heating mode, press "HEAT" button to continue to work heating mode.
7.2 According to the installation place to adjust the wind direction vanes to obtain the best effect.
(380V)
V.1