Minimum to cabinets on either sides of the range
Opening width
30" Model
36" Model
48" Model
60" Model
Exhaust Hood Installation
The bottom of the hood should be 30" min. to 36" above the
countertop. This would typically result in the bottom of the hood
being 66" to 72" above the floor. These dimensions provide
safe and efficient operation of the hood.
After Installation:
1. Check ignition of cooktop burners.
2. Check the air shutter adjustment – sharp blue flame, with no
yellow tipping or lifting flames.
3. Check ignition of oven burner.
4. Visually check tubular burner (oven burner) re-ignition to be
sure both rows of burner ports are relighting each time.
5. Check for gas leaks at all gas connections (using a gas
detector, never a flame).
6. Check oven bake and convection bake function.
Gas Conversion Operation
This cooking range can be used with LP gas and NG gas. It is shipped from the factory adjusted for use with
NG(Nature Gas). Injector for LP gas are included. Follow the instruction shown below for gas conversion.
WARNING
a local professional to complete this procedure. If this procedure isn't completed by a
professional, the warranty can be voided. Forno has the right to ask for a proof (invoice from
the professional) when there is signs of an improper conversion.
W
Opening width
Min.
To wall either side
W
30" (762mm)
36" (914mm)
48" (1219mm)
60" (1520mm)
Gas conversion shall be conducted by a trained professional. Contact
Maximum depth for cabinets above countertop
22
Front edge of
the range side
To countertops
panel forward
below cooktop and
from cabinet
at the range back