3. Remove the back plate. (See Figure 3)
Figure 3
Back Plate
4. Knock out or drill mounting holes as needed.
(See Figure 4)
Figure 4
Mounting Holes
5. Install mounting plate to junction box. Secure
emergency lighting fixture back plate to waterproof
case mounting plate. (See Figures 5-6)
Figure 5
Junction Box
Figure 6
PAGE 2 OF 6
INSTALLATION CONTINUED
Mounting Plate
Mounting
Plate
1-800-295-5510
uline.com
6. Shut off power. Connect unit to single AC power
source. (See Figures 7-8)
NOTE: If using 120 VAC, connect black and white
leads to building utility.
NOTE: If using 277 VAC, connect orange and
white leads to building utility.
NOTE: In some cases, not all leads will be used.
Cap off unused wire.
120 VAC
Connect black and white
leads to building utility.
Cap Unused
Orange Wire
Figure 7
7. After installing emergency lighting, use Phillips
screwdriver to reattach clear cover. Silicone test
button is located on bottom. Restore power and
press test button. LED heads will turn on.
(See Figure 9)
Figure 9
8. Adjust the lamp head
and lens direction.
(See Figure 10)
NOTE: To operate, press the test button. The LED
heads will turn on, and the LED indicator will
turn off. Release the test switch. LED indicator
will turn on, and the LED heads will turn off.
277 VAC
Connect orange and white
leads to building utility.
Cap Unused
Black Wire
Figure 8
Figure 10