PoolDose | pH · ORP · Chlorine
3. ELECTRICAL CONNECTIONS
Clamp
1
Input Probe
2
Input Probe
3
Input Probe
4
Input Probe
5
Input Freq. signal
6
Level (product tank)
7
Level (product tank)
8
Level (External Reed flow sensor)
9
Serial Port
10
Trigger Input 220Vac (High Voltage)
11
Output Relay R1
12
Output Relay R2
13
Output Relay R3
14
Earth connector
15
Power Supply
P1
Peristaltic pump connection
P2
Peristaltic pump connection
P3
Peristaltic pump connection
SekoNet
WiFi Module
Label connections
0000138994
Description
rev. 1.1
Double pump system
PoolDose
pH · ORP
ORP
pH
TEMP (PT100)
Not used
Flow Rate (Freq. Input)
pH Level probe
Chlorine (ORP) level probe
Flow (REED sensor)
Not present
Circulation Pump
(220Vac input)
RL1 AUX1 pH
RL2 AUX2 OPR/Chlorine
RL3 Alarm
Earth
220-240 Vac 50-60 Hz (F/N)
pH
Chlorine (ORP)
Not used
WiFi card (dedicate code)
EN
PoolDose
pH · ORP · CL
ORP
pH
TEMP (PT100)
Free Chlorine
Flow Rate (Freq. Input)
pH Level probe
Chlorine level probe
Flow (REED sensor)
Not present
Circulation Pump
(220Vac input)
RL1 AUX1 pH
RL2 AUX2 OPR/Chlorine
RL3 Alarm
Earth
220-240 Vac 50-60 Hz (F/N)
pH
Chlorine
Not used
WiFi card (dedicate code)
3