PoolDose | pH · ORP · Chlorine
5. SETTING PROGRAM
1
2
Program Setup – Press
At the entry of each menu item, the parameter can be directly modified using the arrow keys (
Confirmation of the current setting and switching to the next item is done by pressing the
The menu has a circular structure: once you arrive at last item, the confirmation of the parameter set by pressing
, determines the return to the first menu item.
1
Language – It is possible to select between 5 available languages: EN, FR, IT, DE, ES
2
pH
§
§
§
* Timed dosing only
§
§
§
3
ORP
§
§
§
* Timed dosing only
§
§
§
4
Chlorine
§
§
§
* Timed dosing only
§
§
5
Advanced menu
§
§
§
§
0000138994
3
4
5
for 5 seconds
Setpoint – 7.4pH (5-9pH)
Setpoint Type: – Acid (Acid/Alka)
Time on = 30seconds (range from 1 to 360 seconds)
Time off = 60seconds (range from 1 to 360 seconds)
Temperature: 25°C; set °C/°F and the manual value
OFA Alarm: Off, 1-60' (minutes)
Setpoint – 700 mV (400-850mV)
Setpoint Type: Low (Low/High)
Time on = 30seconds (range from 1 to 360 seconds)
Time off = 60seconds (range from 1 to 360 seconds)
OFA Alarm: Off, 1-60' (minutes)
Note: The ORP dosing, in the presence of Chlorine has no effect on the dosing pump,
but can handle the Aux2 Relay with ON/OFF activation with respect to the setpoint.
Setpoint – 1.2 ppm(0.3-3.0 ppm)
Setpoint Type: Low (Low/High)
Time on = 30seconds (range from 1 to 360 seconds)
Time off = 60seconds (range from 1 to 360 seconds)
OFA Alarm: Off, 1-60' (minutes)
Circulation pump – (Enabled/Disabled)
In Freq (Input flow rate)
•
OFF/ON
•
Pulse/Liter:1 or Liter/pulse:1 – Set value
•
Unit: L or m³
Calibration pH: 2 points, 1 point, Reference, Disable
Calibration ORP: 1 point, Reference, Disable
rev. 1.1
1) Button to increase the value
2) Button to decrease the value
3) Button Menu/Esc
6
4) Button Cal/OK
5) Button to set the setpoint
6) Digital display
EN
and
).
button.
5