Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

FS-EX310-1
Ring Anchor
Manual
APPLICABLE SAFETY STANDARDS
When used according to instructions, Safewaze Anchors meet ANSI Z359.18-2017 Type A and
OSHA 1910.140, 1926.502 regulations. Applicable standards and regulations depend on the
type of work being done and may include state-specific regulations. Refer to local, state, and
federal requirements for additional information on the governing of occupational safety regarding
Personal Fall Arrest Systems (PFAS).
The anchor connector has been tested in compliance with requirements of ANSI/ASSE Z359.7.
The testing does not extend to the substrate to which the anchorage connector is attached.
WARNING:
The manufacturer's instructions must be provided to users of this equipment. The user must
follow the manufacturer's instructions for each component of the system. The user must read and
understand these instructions before using this equipment. Manufacturer's instructions must be
followed for proper use and maintenance of this equipment. The user must understand how to
safely and effectively use the FS-EX310-1 ring anchor and all equipment used in conjunction with
the FS-EX310-1. Alterations to this product, misuse of this product, or failure to follow instructions
may result in serious injury or death. Avoid moving machinery, sharp and/or abrasive edges, and
any other hazard that could damage or degrade the component.
Do not throw away instructions!
Read and understand instructions before using equipment!
IMPORTANT:
• Questions regarding the use, care, or suitability of this equipment for your application?
Contact Safewaze.
• Only Safewaze, or entities authorized in writing by Safewaze, may make repairs to
Safewaze fall protection equipment.
• Record all important product information below prior to use. Documentation of all
Competent Person annual inspections is required in the Inspection Log.
INTRODUCTION
Thank you for purchasing a Safewaze Anchorage Connector. This manual must be read and
understood in its entirety and used as part of an employee training program as required by
OSHA or any applicable state agency. This manual and any other instructional material must be
available to the user of the equipment. Every user must be trained in the inspection, installation,
operation, and proper usage of the anchor.
SPECIFICATIONS
• Capacity: The FS-EX310-1 Ring Anchor is designed to provide a fall protection
anchorage for a single user with maximum weight of 420 lbs.
• The anchor is reusable.
• Three 5/16 in. x 3 in. Hex Lag Screws are included with the anchor.
• Length of anchor is 9''.
• Minimum Breaking Strength is 5,000 lbs. (22kN).
• Minimum Service Temperature is -35°F (-37°C).
• 5,000 lbs. anchor point when used for Horizontal Lifeline (HLL) applications/single point
anchorage applications limited to a 30° work angle.
• 3,600 lbs. anchor point when used as a single point anchorage with 360° work
operations.
USER INFORMATION
Date of First Use:
Trainer:
Serial Number:
User:
I
Address: 225 Wilshire Ave SW, Concord, NC 28025
WORKER CLASSIFICATIONS
Read and understand the definitions of those who work in proximity of, or may be
Qualified Person: "Qualified Person" means one who, by possession of a recognized degree,
certificate, or professional standing, or who by extensive knowledge, training, and experience,
has successfully demonstrated their ability to solve or resolve problems relating to the subject
matter, the work, or the project.
Competent Person: "Competent Person" means one who is capable of identifying existing and
predictable hazards in the surroundings or working conditions which are unsanitary, hazardous,
or dangerous to employees, and who has authorization to take prompt corrective measures to
eliminate them.
Authorized Person: "Authorized Person" means a person approved or assigned by the
employer to perform a specific type of duty or duties, or to be at a specific location or locations,
at the jobsite.
It is the responsibility of a Qualified or Competent Person to supervise the jobsite and
LIMITATIONS
Never exceed a free fall distance of 6 ft. A free fall of more than 6 ft. could cause excessive arrest
forces that could result in serious injury or death.
Safewaze Anchors have a maximum capacity of ANSI 310 lbs./OSHA 420 lbs. including any
tools, clothing, accessories, etc., unless otherwise rated by Safewaze.
Structures for attachment of Safewaze Anchors shall support a minimum 5,000 lbs. (22 kN) or be
designed with a safety factor of two by a Qualified Person.
Fall Clearance: There must be sufficient clearance below the anchorage connector to arrest a
fall before the user strikes the ground or an obstruction. When calculating fall clearance, account
for a MINIMUM 2' safety factor, deceleration distance, user height, length of lanyard/SRL, and all
other applicable factors (Figure 1).
*This diagram is an example of fall clearance calculation ONLY.
Required
Distance
from
Anchorage
(17.5' Total)
Swing Falls: Prior to installation or use, make considerations for eliminating or minimizing all
swing fall hazards. Swing falls occur when the anchor is not directly above the location where
a fall occurs. Always work as close to, or in line with, the anchor point as possible. Swing falls
significantly increase the likelihood of serious injury or death in the event of a fall (Figure 2).
SPECIFIC ANCHOR APPLICATIONS
Personal Fall Arrest: Safewaze Anchors are designed as an anchor point to support a
maximum of 1 PFAS when utilized for fall protection applications. The structure to which
the anchor is attached must withstand loads applied in the directions permitted by the
system of at least 5,000 lbs. (22kN). Maximum allowable free fall is 6 ft. The allowable
attachment point to the harness is the Dorsal D-ring.
Restraint: Safewaze Anchors are authorized for use in Restraint applications. The
structure to which the anchor is attached must withstand loads applied in the directions
permitted by the system of at least 1,000 lbs. NO free fall is permitted. Restraint systems
may only be used on surfaces with slopes up to 4''/12'' (vertical / horizontal). For
Restraint applications, the allowable attachment points to the harness are Dorsal D-ring,
Front/Sternal D-ring, Side D-rings, and Shoulder D-rings.
Phone: 800-230-0319
Fax: 704-262-9051
exposed to, fall hazards:
ensure safety regulations are complied with.
FIGURE 1: FALL CLEARANCE DIAGRAM
For all applications, worker weight capacity range
(including all clothing, tools, and equipment) is
ANSI 130-310 lbs./OSHA up to 420 lbs.
Lanyard Length
(6' Total)
Deceleration
Distance (3.5' Total)
Height of Harness Dorsal
D-ring from
Worker's Feet
(6' Total)
Safety Factor
(2' Total)
FIGURE 2: SWING FALL
A
FALL-ARREST
I
Email: info@safewaze.com
Work Positioning: Safewaze Anchors are authorized for use in Work Positioning
applications. Work Positioning allows a worker to be supported during suspension while
freeing both hands to conduct work operations. The structure to which the Anchor is
attached must withstand loads applied in the directions permitted by the system of at
least 3,000 lbs. Maximum allowable free fall is 2 ft. For positioning applications, the
allowable attachment points to the harness are the Side D-rings.
Rescue/Confined Space: Safewaze Anchors are authorized for use in Rescue/Confined
Space applications. Rescue systems are utilized to safely recover a worker from a
confined location or after exposure to a fall. Composition of rescue systems can vary
based upon the type of rescue involved. The structure to which the Anchor is attached
must withstand loads applied in the directions permitted by the system of at least 3,100
lbs. NO free fall is permitted. For rescue applications, the allowable attachment points to
the harness are Dorsal D-ring, Front/Sternal D-ring, and Shoulder D-rings.
ANCHORAGE INSTALLATION LOCATION
A Qualified Person or Engineer must conduct an analysis of the workplace and anticipate where
workers will be performing their duties. An anchorage location selected for a PFAS must have a
strength capable of sustaining a static load applied in the direction permitted by the PFAS of at
least:
• Two times the maximum arrest force permitted when certification exists, or
• 5,000 lbs. (22kN) in the absence of certification.
COMPATIBILITY OF COMPONENTS/CONNECTORS
• Unless otherwise noted, Safewaze equipment is designed for, and tested with, associated
Safewaze components or systems. Substitutions or replacements made with competitor's
components or subsystems may jeopardize compatibility of equipment, possibly affecting
the safety and reliability of the overall system.
• Connectors are compatible with connecting elements when they have been designed
to work together in such a way that their sizes and shapes do not cause their gate
mechanisms to inadvertently open regardless of how they become oriented.
• Connectors (hooks, carabiners, and D-rings) must be capable of supporting at least 5,000
lbs. (22 kN).
• Connectors must be compatible with the anchorage or other system components.
• Do not use equipment that is not compatible. Non-compatible connectors may
unintentionally disengage (Figure 3).
• Connectors must be compatible in size, shape, and strength.
• Self-locking snap hooks and carabiners are required by ANSI Z359 and OSHA guidelines.
• Some specialty connectors have additional requirements. Contact Safewaze if you have
any questions about compatibility.
FIGURE 3: UNINTENTIONAL DISENGAGEMENT
1. Non-Compliant Part
3. Gate Opens
2. Gate Presses
Against
Non-Compliant Part
Disengage
Using a connector that is undersized or irregular in shape (1) to connect a snap hook or carabiner
could allow the connector to force open the gate of the snap hook or carabiner. When force is
applied, the gate of the hook or carabiner presses against the non-compliant part (2) and forces
open the gate (3). This allows the snap hook or carabiner to disengage (4) from the connection
point.
MAKING CONNECTIONS
Snap hooks and carabiners used with this equipment must be double locking and/or twist lock.
Ensure all connections are compatible in size, shape, and strength. Do not use equipment that is
not compatible. Ensure all connectors are fully closed and locked.
Safewaze connectors (hooks, carabiners, and D-rings) are designed to be used only as specified
in each product's manual. See Figure 4 for examples of inappropriate connections. Do not
connect snap hooks and carabiners:
• To a D-ring to which another connector is attached.
• In a manner that would result in a load on the gate (with the exception of tie back hooks).
• In a false engagement, where features that protrude from the snap hook or carabiner
catch on the anchor, and without visual confirmation seems to be fully engaged to the
anchor point.
• To each other.
• By wrapping the web lifeline around an anchor and securing to lifeline, except as allowed
for tie back models.
• To any object which is shaped or sized in a way that the snap hook or carabiner will not
close and lock, or that roll-out could occur.
• In a manner that does not allow the connector to align properly while under load.
FIGURE 4: INAPPROPRIATE CONNECTIONS
Large throat snap hooks must not be connected to standard size D-rings or similar objects which
will result in a load on the gate if the hook or D-ring twists or rotates, unless the snap hook
complies with ANSI Z359.1-2007 or ANSI Z359.12 and is equipped with a 3,600 lb. (16 kN) gate.
Website: safewaze.com
4. Parts

Publicidad

loading

Resumen de contenidos para SafeWaze FS-EX310-1

  • Página 1 Safewaze components or systems. Substitutions or replacements made with competitor’s components or subsystems may jeopardize compatibility of equipment, possibly affecting Structures for attachment of Safewaze Anchors shall support a minimum 5,000 lbs. (22 kN) or be the safety and reliability of the overall system.
  • Página 2 Snap hooks and carabiners must be self-locking and self-closing and must never be hooked to each other. 1. To install the FS-EX310-1 Ring Anchor, place the anchor on the truss with its flat end pointed • A Competent Person must conduct an analysis of the workplace and anticipate where down.
  • Página 3 Safewaze determine otra cosa. • A menos que se indique otra cosa, el equipo de Safewaze ha sido diseñado y probado Las estructuras a las cuales se fijen las anclas de Safewaze deben soportar un mínimo de NORMAS DE SEGURIDAD APLICABLES con componentes o sistemas asociados de Safewaze.
  • Página 4 (Figura 6). certificado para eso. 2. La FS-EX310-1 se puede volver a usar e instalar. Los fijadores se pueden volver a usar si se hacen agujeros piloto antes de instalarlos. Los agujeros piloto deben ser de 7/32 plg.