Descargar Imprimir esta página

Milwaukee LDM 50 Manual Original página 3

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 74
TECHNICAL DATA
Dust and Water resistance
Receiving Lens
Focus
Maximum Measuring Range
Minimum Measuring Range
Absolute Accuracy @ < 10m
Repeatability Accuracy @ < 10m
Repeatability Accuracy @ > 10m
Measurement Time
Display Type
Power Type
Battery Life
Laser Output Power
Laser Spot Size
Laser Class
Laser Type
Laser Radiation Vertical Angle
Laser Radiation Horizontal Angle
Device auto off time
Laser auto off time
Operating Temperature Range
Storage Temperature Range
Weight without Battery
SPECIFIED CONDITIONS OF USE
The laser distance measurer can be used for measuring distances and tilts.
Do not use this product in any other way as stated for normal use.
ENGLISH
IP54
14 mm
35 mm
50 meters (Tolerance : 55m)
0.05 meters
± 1.5 mm (Max)
± 1.5 mm (Max Typical, 2σ)
Increase ± 0.25 mm / meter (Max Typical, 2σ)
0.5 s
LCD ( 22.7 mm x 31 mm )
AAA 2x (Alkaline Battery)
10000 (Single Measure)
0.6 mW ~ 0.95 mW (Class 2, 650nm )
25 x 30 mm @ 16 m (Max)
2
650 nm, < 1 mW
+1 degree
±1 degree
180 seconds
30 seconds
-10°C to +50°C
-25°C to +70°C
80 g
ERROR CODE TABLE
Code
Description
Out of measuring range
Err01
Reflect signal is too weak
Err02
Out of display range (max value:
Err03
99.999) e.g. result of area or volume
is out of display range
Pythagorean calculation error
Err04
Battery is low
Err05
Out of working temperature
Err06
Ambient light is too strong
Err07
Solution
Measure in a proper range
Choose a better surface
Check and verify values and steps
are correct
Check and verify values and steps
are correct
Install new batteries
Measure in an environment with the
specified working temperature
Measure in a darker place (shadow
target)
2

Publicidad

loading