CHANGES IN MEASURING UNITS
The meter can be configured to use grams [g], kilograms
[Kg], ounces [Oz] and pounds [Lb].
SETTING THE UNITS
Access the "UNITS" submenu according to the section
"CALIBRATION PROCEDURE" (page 6). In order to entry in
the "UNITS" submenu, press ON/RESET button (Fig. 31)
once the screen is blinking (Fig. 32).
Fig. 31
TROUBLE-SHOOTING
SYMPTOM
The meter
is inaccurate.
Reduced flow.
The meter does not count.
8
105 300 R. 09/23
Fig. 32
Oz
lb
Fig. 35
POSSIBLE CAUSE
A fluid with very high or very low viscosity
is being used.
Very high or low fluid temperature.
The meter is working outside its field of
application (see technical specifications).
Dirt in the measuring chamber.
Faulty read sensor.
Alentec & Orion AB Grustagsvägen 4, SE-13840, Älta, SWEDEN · info@alentec.se · www.alentec.com
When making a change from one unit to another, the
conversion of the quantity stored is made both in the partial
meter and in the total meter.
After this, the display will show the selected measurement
units (Fig. 33). Press SELECT button (Fig. 34) successively
until visualizing the required measurement unit (Fig. 35).
To select the unit and save configuration, press ON/RESET
button (Fig. 36). After that, the meter will exit to the
dispensing mode automatically (Fig. 37).
Fig. 33
Fig. 36
SOLUTION
Calibrate the meter.
Adjust the operating conditions to the
meter working range.
Clean the measuring chamber.
Contact with the Technical Service.
g
Kg
Fig. 34
Oz
lb
Fig. 37