To create a synced group, using the MOWIN APP, do the following:
1) Position all actuator trimmers to be synchronized in M (SLAVE actuator state)
2) Place only the trimmer of one of the actuators in "A" (MASTER actuator status)
3) Power the MASTER actuator (or all actuators)
4) Create a "new synchronization" by following the Step by Step APP
7.3
CHAIN STROKES ADJUSTMENT
It is possible to adjust the stroke of the chain millimetrically through theAPP or manually through the special trimmer on the
front of the actuator. Below is the table with the various chain lengths corresponding to the positions of the trimmer.
TRIMMER POSITION M
TRIMMER POSITION 1
TRIMMER POSITION 2
TRIMMER POSITION 3
TRIMMER POSITION 4 (Factory setting)
TRIMMER POSITION A
* the actuator does not move unless it has first been synchronised with a MASTER actuator;
** The WIFI of the actuator is active and it is therefore possible to interact through the Mowin app. On the OPEN command, the actuator
makes the maximum stroke.
7.4
REPLACING A FAULTY ACTUATOR FROM A GROUP OF SYNCHRONIZED ACTUATORS
If it is necessary to replace a device in a synchronized group, proceed as follows:
1) Disconnect the actuators from the window;
2) Reset the actuators using the reset procedure ("8
3) Activate the actuators individually by setting the trimmers to the stroke position and locate the faulty one;
4) Replace the non-functioning actuator with a new one;
5) Perform the manual or APP synchronization procedure.
7.5
ADDING OR REMOVING AN ACTUATOR FROM A SYNCHRONIZED GROUP
To add or remove one or more actuators from an already synchronized group, it is necessary to reset the synchronized group
and perform a new synchronization procedure.
8
RESET PROCEDURE
The reset procedure allows the actuators to be returned to factory conditions. It is necessary to perform a RESET in the following
cases:
1) Actuators are to be reset to factory settings.
2) Synchronization failed.
3) The number of synchronized actuators must be increased or decreased.
4) It is necessary to replace an actuator on a group of synchronized actuators.
To perform a reset, proceed as follows:
1) Disengage the actuator(s) from the window.
2) Power the actuator(s) to be reset.
3) With the actuator(s) powered, move the Trimmer following the M-C-M-C-M-C-M sequence within 5 sec ("C" stands for stroke
and corresponds to one of positions 1-2-3-4).
4) The trimmer flashes three times.
5) At the end of the operation, all the motors will be reset to factory conditions and the LEDs will remain lit.
N.B.: In the case of a group of synchronized actuators, if all are energised, simply reset the MASTER and the SLAVEs will also
be reset.
Once the reset operation is complete and the trimmer is set to 'M', the actuator will not accept any opening or closing
commands.
Once the reset operation is completed, the actuator will only accept a complete closing command.
44
STROKES SELECTABLE BY SNAP TRIMMERS
* SLAVE actuator status
120mm STROKE
300mm STROKE
350mm STROKE
400mm STROKE
** MASTER actuator/Wi-Fi status active