note:
The machine will stop automatically and turns in reverse direction for 1 second and continue counting in
following conditions:
Coin Jam
All the coins are counted
If the counting sensor can not find any coin in 3 seconds again, the machine will reverse and stop automatically.
When a batch number is set (3.6) and the count total reaches the batch quantity, the machine will stop
immediately. Press [START/STOP] again to continue counting.
3.3 cLeaR coUnTInG ReSULTS
When finished counting, press [CLR] to delete the counting results.
The screen displays "0".
If the present counting should be stopped halfway, press START/
STOP key, the counting will stop. With START/STOP key pressed
again, the machine will restart. The previous counts are retained and
new count will be added to them.
3.4 MeMoRy FUncTIon
To store counting results press [M]. The machine stores the results
in memory and clears the display back to [0]. When proceeding
counting press [M] again to add the new counting results to the
memory.
To view the counting results from memory press 'n hold [M] for
5 seconds.
The screen will display the total counting results stored in memory.
3.5 aDD FUncTIon (accUMULaTIon MoDe)
Press [ADD] to add up multiple counts.
When ADD function is activated the "ADD" indicator light lights up.
3.6 BaTcH MoDe
3.6.1 Batch counting using the numeric keys
Use the numeric keys to set a specific batch amount. Press [START/
STOP] to start counting. The machine automatically stops when the
batch amount is reached.
Press [CLR] to clear the current batch amount.