Descargar Imprimir esta página

Craftsman 919.167242 Manual página 18

Ocultar thumbs Ver también para 919.167242:

Publicidad

Idiomas disponibles

Idiomas disponibles

To Replace
Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
3.
Using an adjustable
wrench
remove the gauges and quick
connect from the regulator.
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple on the standpipe.
6.
Assemble the regulator and
orient as shown.
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
7.
8.
Reapply pipe sealant to gauges
and quick connect.
Reassemble gauges and quick
connect. Orient gauges to read
correctly. Tighten quick connect
with wrench.
Before you store the air compressor,
make sure you do the following:
1.
Review the "Maintenance"
section on the preceding pages
and perform scheduled
maintenance as necessary.
2.
Set the On/Auto/Off
lever to
"OFF" and unplug unit.
3.
Turn the regulator
counterclockwise
and set the
outlet pressure to zero.
4.
Remove the air tool or
accessory.
5.
Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 psi. Release safety valve ring.
6.
Drain water from air tank by
opening drain valve on bottom of
tank.
Risk of Bursting.
Water will
condense in the air tank.
If not
drained, water will corrode and
weaken the air tank causing a risk
of air tank rupture.
7.
After the water has been drained,
close the drain or drain valve.
NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cleaned, then
reinstalled.
8.
Protect the electrical cord and air
hose from damage (such as
being stepped on or run over).
Wind them loosely around the
compressor
handle. (If so
equipped)
9.
Store the air compressor in a
clean and dry location.
D30085
18-ENG

Publicidad

loading