2.2.3 t
/t
urn on
urn off
The switch must be at the OFF position, i.e. the «0» is
visible. To switch ON the tool, press the switch, and push
it forwards until it engages audibly, i.e. the «1» becomes
bisible. Press the ON/OFF swith to trigger the blocking
and the machine shuts down.
2.3 r
Ating dAtA
Voltage
No-load speed
Sound pressure level IEC 62841
Noise emission level IEC 62841
Vibration IEC 62841
Weight w/o battery
Protection class
The specified vibration value was measured with a
standardised test procedure. It can be used to
compare products or to make an initial assess-
ment of the exposure. The vibration emissions may differ
from the specified value, depending on how the power
tool is used. Operating personnel must be protected with
defined safety measures based on the estimated expo-
sure under the actual conditions of use (these must take
into account all phases of the operating cycle, e.g. the
times when the power tool is switched OFF and the times
it is switched ON, but is not under load).
2.4 o
PerAting conditions
Temperature range during operation: 0 to +50°C
Relative air humidity: 95% at +10°C not condensed
3.1 P
Always attach the particle guard to the handle over the
ventilation slots before working in heavily contaminated
18V DC
environments or on materials generating high dust levels.
5250min
-1
85dB(A), K=3dB(A)
3.2 r
96dB(A), K=3dB(A)
7.5m/s
, K=1.5m/s
2
2
2kg
III
The battery pack can be rotated relative to the stator
housing in steps of 90° which enables the battery pack
to be brought into a more easily accessible position for
special work operations.
Keep button pressed and carefully rotate the battery pack
into the desired position until it engages audibly.
3.3 g
speed of the machine. Use only clean tools!
3.
haNDLINg
rotectiVe deVice
B
otAtion of the
Attery PAcK
rinding tools
Use only grinding tools whose ad-
missible maximum speed is equal
to or higher than the no-load
/ o
PERaTIoN
23