Descargar Imprimir esta página

TESY MAXEAU GCV 2005620 D06 SRC Instrucciones De Uso Y Mantenimiento página 9

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
Water heaters fitted with a supply cord without a plug.
The appliance has to be connected to a separate electricity circuit of the
stationary electrical wiring.The connecting has to be constant- with no plug
contacts. The circuit has to be supplied with a safety fuse (16A) and with
inbuilt device to ensure disconnection of all pole pieces in the conditions of
over-voltage from category III.
The connecting of the conductors of the supply cord of the appliance has to
be carried out as follows:
conductor with brown insulation – to the phase conductor of the
electrical wiring (L)
conductor with blue insulation- to the neutral conductor of the wiring (N)
conductor with yellow-green insulation – to the safety conductor of the
wiring (
)
3.2.
Models without power cord
The appliance has to be connected to a separate electricity circuit of the
stationary electrical wiring. The circuit has to be supplied with a safety fuse
16A (20A for power > 3700W). Copper single core (rigid – non stranded)
conductor shall be used for the connection – cable 3 x 2.5mm² (cable 3 x
2.5mm² for power > 3700W).
The electrical circuit supplying the appliance must have an in-built device
ensuring the splitting of all terminal poles under conditions of super-voltage
of category III.
To install the power supply wire to the boiler, remove the plastic cover
(Fig.2).
Connect the power wires in compliance with the marks on the terminals, as
follows:
the phase - to mark A, A1, L or L1;
the neutral - to N (B or B1 or N1)
The safety wire must be obligatory connected to the screw joint marked
with
.
After the installation, put the plastic cover back in its place!
Explanations to Fig. 3:
TS - thermal switch; TR - thermal regulator; S - switch (for models that have
one); R - heater; IL - light indicator
VI.
RUST PROTECTION MAGNESIUM ANODE (FOR WATER
HEATERS WITH WATER TANKS COVERED BY GLASS-CERAMICS
COATING)
The magnesium anode protects the water tank's inner surface from
corrosion.
The anode element is an element undergoing wear and tear and is subject
to periodic replacement.
In view of the long-term and accident free use of your water heater, the
manufacturer recommends periodic inspections of the magnesium anode's
condition by a qualified technician and replacement whenever required,
and this could be performed during the appliance's technical preventive
maintenance. For replacements, please contact the authorized service
stations!
OPERATION.
VII.
1.
Switch on.
Before switching on the appliance for first time, make sure that the boiler
is properly connected to the power supply network and full with water.
The boiler is switched on by a switch integrated into the installation,
described in item 3.2 of Section V, or upon connecting the plug to the
electrical contact (in the case of an extension cable with plug).
2.
Water heaters with electromechanical control
Fig. 2 where:
1 - Moisture-proof button for heater switching (for models with a switch)
2 - Light indicator
3 - Regulator handle (only for models with adjustable thermostat)
When there is in-built in switch in the water heater, you must switch
it on.
Electrical switch with one knob:
0 – switched off;
I – switched on;
The knob lit when the switch is on.
The control lamp on the panel indicates the state (the mode) in which the
appliance is placed: it is lit when the water is being heated and is switched
off when the specified by the thermostat water temperature level is reached.
Electrical switch with two knobs:
0 - switched off; I; II - switched on;
Choosing of different power levels of heating:
Rated power (marked
Switched on
on the rating label)
knob (I)
1600 W
800 W
2000 W
800 W
2400 W
1200 W
The buttons of the switch lit on, if they are switched on and during heating.
They stops to lit when the preset temperature of the water is reached and
the thermostat switch-off the voltage supply.
The control lamp lit on when there is supply voltage from electrical main.
It does not lit on when there is not supply voltage or the thermal cut-out
(temperature protection) is switched off (see 3 below).
English
Switched on
Switched on
knob (II)
knob I and II
800 W
1600 W
1200 W
2000 W
1200 W
2400 W
Temperature setup (for models with adjustable thermostat).
This setup allows the gradual setting of the desired temperature, achieved by using a
handle on the control panel.
e
Position
(Energy-save mode) – At this mode, water temperature reaches
up to approximately 60°С. Heat losses are reduced in this way.
Fig. 2a indicates the direction of rotation of the knob for the other models
with externally adjustable thermostat.
Attention! Place the thermostat knob in position for maximum
temperature (unless it is on this position constantly), for period of one
day each month. This ensures higher hygiene of the used hot water.
3.
Protection according to the temperature (valid for all models).
The appliance is equipped with a special facility (thermal circuit-breaker)
for protection against over-heating of the water, which is switching off the
heater from the electricity network, when the temperature reaches too high
values.
Attention! When this device operates, it does not self-reset and the
appliance will not work. Please call an authorized service for solving
the problem.
MODELS EQUIPPED WITH A HEAT EXCHANGER (SERPENTINE TUBE).
VIII.
These are appliances with inbuilt heat exchanger and are intended to be
connected to the heating system with maximum temperature of the heat
carrier of 80°C.
The control over the flow through the heat exchanger is a matter of
solution for the particular installation, whereby the choice should be made
at its design (e.g. external thermostat that measures the temperature in
the water tank and operates a circulation pump or a magnet valve).
Water heaters with a heat exchanger provide the opportunity for the water
to be heated in two ways:
1.
by means of a heat exchanger (coil) – a primary way of heating the water,
2.
by means of an auxiliary electrical heating element with automatic operation,
built in the appliance – it is used only when additional heating of the water is
needed or in case of repairs to the system of the heat exchanger (coil). The proper
way of connecting the appliance to the electric network and how to work with it has
been specified in the previous paragraphs.
Mounting:
In addition to the mounting manner outlined above, especially for the latter
models, it shall be required to connect the heat exchanger to the heating
installation. The connections are to be carried out in observance of the
direction indicated by the arrows on Fig. 1е.
Technical parameters (table 6):
Surface of serpentine [m²] - S;
Volume of serpentine [l] - V;
Operational pressure of serpentine [MPa] - P;
Maximum temperature of heat carrier [°C] - Tmax.
We recommend you mount stopcocks at the heat exchanger's entry and exit
points. By stopping the flow of the thermophore via the lower (stopcock) you
shall avoid the unnecessary circulation of the thermophore during periods of
use only of the electric heating element.
Upon disassembly of you water heater equipped with a heat exchanger
you must close both stopcocks.
There is a connexion with internal thread of ½" welded to the water tank
for the purposes of installing thermal probe – marked with „TS". The
appliance is fitted with brass pocket for a thermal probe which should be
screwed into the aforesaid connexion.
The usage of dielectric bushings for connecting the heat exchanger to
an installation of copper pipes is obligatory.
For ensuring minimal corrosion, pipes with a limited diffusion of
gasses must be used in the installation.
IX.
PERIODIC MAINTENANCE
In the conditions of normal use of the water heater, under the influence of high
temperature, limestone (the so-called lime scale) deposits on the surface of the
heating element. This worsens the heat exchange between the heating element
and the water. The temperature on the surface of the heating element and around
it increases. Specific noise can be heard – of boiling water. The thermoregulator
begins to switch on and off more frequently. A "deceptive" activation of the
thermal protection is possible. Due to these facts, the manufacturer recommends
preventive maintenance of your water heater every two years by an authorized
service centre or service facility, this service remaining at the customer's expense.
This preventive maintenance should include cleaning and examination of the
anode protector (for water heaters with glass-ceramic coating), which has to be
replaced with a new one, if necessary.
To clean the appliance, use a damp cloth. Do not use abrasive or solvent-
containing detergents.
The manufacturer does not bear responsibility for any consequences
arising from non-adherence to these instructions.
Instructions for protection of the environment
Old electric appliances contain valuable materials and must not be
disposed of with the domestic waste! Please contribute actively for
the protection of the resources and the environment and dispose of
the appliance in the buy-back centres organized for this purpose
(if such are available).
EN
7

Publicidad

loading