DIR 1000722R0001 Version 04 - 140G-J_, 140MG-J_
Circuit Breaker Installation Instructions for 140G-J, 140MG-J
Istruzioni di installazione
Installationsanleitung
Instructions pour l'installation
Instrucciones de instalación
安装说明
Installation - Installazione - Installation - Installation -
Instalación - Instalação -
WARNING:
To prevent electrical shock, disconnect from power source before
installing or servicing. Install in suitable enclosure. Keep free from contaminants.
70E requirements
Per prevenire infortuni, togliere tensione prima dell'installazione o
manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
WARNUNG: Vor Installations- oder Servicearbeiten Stromversorgung zur
Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem
passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden.
AVERTISSEMENT: Avant le montage et la mise en service, couper l'alimentation
secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire
appropriée. Protéger le produit contre les environnements agressifs.
ADVERTENCIA: Desconéctese de la corriente eléctrica, antes de la instalación o
del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada.
Manténgalo libre de contaminantes.
ATENÇÃO: Para evitar choques, desconectar da corrente elétrica antes de fazer a
instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de
contaminantes.
警 :感電事故防止のため、取付けまたは修理の際は電源から取り外してく
ださい。適切なケース内に取付けてください。また、汚染物質がないことを
確認してください。
警告:为了防止触电,在安装或维修之前必须先切断电源。安装在合适的设备
箱内。防止接触污染物。
Mounting hardware
LENGTH
M
85 mm (3.35")
M4
140G-H-MH4
3p
2
140G-H-MH4
4p
2
Publication 140G-IN106E-EN-P - November 2020
-
Phase
barrier
CH 7
CH 6
M
M 4
140G-H-PB3M
140G-J-ECM
2
2
4
140G-H-PB4M
140G-J-ECM4
2
2
6
140G-J, 140MG-J
CLACK
Carter
End cap kit
LENGTH
dia.
LENGTH
M
1 2 mm (0.47" )
3
1 8 mm (0.71 " )
M 4
140G-J-SC3
6
1
140G-J-SC4
8
1
1
Side
Insulator
cover
140G-J-BP3
2
2
-
140G-J-BP4
2
2
-
Bul. 140G/140MG
Required
Tools
xx lb-in
xx Nm
PH 1

Publicidad

loading

Resumen de contenidos para Allen-Bradley 140G-J

  • Página 1 Bul. 140G/140MG DIR 1000722R0001 Version 04 - 140G-J_, 140MG-J_ Circuit Breaker Installation Instructions for 140G-J, 140MG-J Istruzioni di installazione Installationsanleitung Instructions pour l’installation Instrucciones de instalación 安装说明 Installation - Installazione - Installation - Installation - Instalación - Instalação - 140G-J, 140MG-J...
  • Página 2 Circuit Breaker Installation Instructions for 140G-J, 140MG-J 140G-J20 IEC - 500V<Ue<750VDC IEC - 500V < Ue < 750VDC (except 140G-J20) UL - 480V<Ue<600V UL- Ue< 480V Breakers and accessories are tested for conformance to governing body standards with insulated cable or busbar. Any other configuration must be tested in the installation at the cost of the customer.
  • Página 3 Circuit Breaker Installation Instructions for 140G-J, 140MG-J Cannot be reverse 2.05"/52.5 mm 0.67"/17.5 mm wired (fed) above 600V UE>600V dia. 0.18" 4p ONLY LINE Ø 4.5 mm - M4 4p ONLY 3p ONLY LOAD 4p ONLY REFER TO FIG. 1-2 2.72"...
  • Página 4 Circuit Breaker Installation Instructions for 140G-J, 140MG-J Panel drilling templates 2.07" (52.5 mm) 0.69" 0.69" 0.69" min 0.41" (17.5 mm) (17.5 mm) (17.5 mm) min 10.5 2.74" 2.74" dia. min 0.33" (69.5 mm) (69.5 mm) dia. 0.33" 5.47" (139 mm) 0.31"(8) max...
  • Página 5 Circuit Breaker Installation Instructions for 140G-J, 140MG-J IEC Spacing 140G-J2, -J3, -J6, -J0 Busbar/Flexibar Cables 2.5...10mm 16...185mm 4" (100mm) 7.87" 2.76" 2.76" (200mm) 2.0" (70mm) (70mm) (50mm) 7.87" (160mm) 4" (100mm) 2.0" Conductor support Distance (50mm) (mm) 7.87" 140G-J2,J3,-J6,-J0 (200mm) AC >440V...
  • Página 6 Circuit Breaker Installation Instructions for 140G-J, 140MG-J UL Spacing Ue<480V Busbar/Flexibar Cables 7.87" 4.0" (200mm) (100mm) 7.87" 4.72" 4.72" (200mm) 2.36" (120mm) (120mm) (60mm) 4.33" (110mm) 1.77" 1.77" (45mm) (45mm) 6.3" (160mm) 4.33" (110mm) 2.36" 7.87" (60mm) (200mm) 7.87" 4.0"...
  • Página 7 Circuit Breaker Installation Instructions for 140G-J, 140MG-J UL Spacing 600V Busbar/Flexibar Cables 7.87" 4.0" (200mm) (100mm) 4.72" 4.72" 7.87" (120mm) 2.36" (120mm) (200mm) (60mm) 4.33" (110mm) 1.77" 1.77" (45mm) (45mm) 6.3" (160mm) 4.33" (110mm) 7.87" 2.36" (200mm) (60mm) 7.87" 4.0"...
  • Página 8 Circuit Breaker Installation Instructions for 140G-J, 140MG-J ONLY REQUIRED FOR THROUGH THE DOOR APPLICATION CH 2.5 ≤ (WITH DOOR OF THE PANEL 0.98"/25mm FROM THE FRONT) 4.4 lb-in 0.5 Nm Panel Board Mounting 140G-J20 750VDC 3p - 8.0" (205mm) - Mandatory insulating plate for 4p - 9.5"...
  • Página 9 Circuit Breaker Installation Instructions for 140G-J, 140MG-J IEC DC Publication 140G-IN106E -EN-P - November 2020 DIR 1000722R0001 (Version 04)
  • Página 10 Circuit Breaker Installation Instructions for 140G-J, 140MG-J REQUIRED: Trip Unit Protection Settings Adjustment RICHIESTO: Regolazione delle impostazioni di protezione dell'unità di sgancio ERFORDERLICH: Einstellung der Auslöseeinheiten-Schutzeinstellungen REQUIS: Réglage des paramètres de protection du déclencheur NECESSÁRIO: Ajuste das configurações de proteção da unidade de disparo REQUERIDO: Ajuste de la configuración de protección de la unidad de disparo...
  • Página 11 Circuit Breaker Installation Instructions for 140G-J, 140MG-J 140G-J_E_ , 140G-J_F_: 140G-J THERMOMAGNETIC TRIP UNIT - Manually trip the breaker prior to adjustment of the magnetic settings. DC only - For the protection thresholds against short-circuits a correction value of 1.5(correction factor of AC thresholds using the breaker in DC) shall be used, according to the type of distribution network.
  • Página 12 Guia de solução de problemas de LED Guía de resolución de problemas de LED LED 故障排除指南 Trip Unit Input Module for Sense Trip Units for 140G-H, 140G-J, 140MG-H, 140MG-J Modulo di ingresso dell'interruttore 140G-H, 140G-J, 140MG-H, 140MG-J Unterbrecher-Eingangsmodul 140G-H, 140G-J, 140MG-H, 140MG-J 140G-IN241 Módulo de entrada do interruptor 140G-H, 140G-J, 140MG-H, 140MG-Jr...