INSTALLATION
Wiring diagram
220–240 V
50 Hz
L
N
basicDIM
12 – 24 V constant
Wireless
L
N
voltage Driver
PWM CV CH
mm²
– mm
solid
eindrähtig
monobrin
a filo unico
monofilar
entrådig
tc
tc (bottom)
03/22-15013092-2 We reserve the right to make technical changes without prior notice.
Tridonic GmbH & Co KG, www.tridonic.com, info@tridonic.com, Tel. +43 5572 395-0
The basicDIM Wireless PWM CV 4CH module is a four-channel PWM dimmer
UK
for constant voltage LED loads, such as LED strips and constant voltage LED
modules, which can be controlled via Bluetooth. basicDIM Wireless PWM CV
4CH module is supplied with 12–24 V DC. The LED load is connected at the
output.
Technical Data
DC voltage range (inputs/outputs)
Max. input current
Max. output current
Output power
Typ. power draw in stand-by
Operating frequency radio receiver
Max. output power radio receiver
Ambient temperature
tc point
Storage temperature
Dimensions L x W x H
Degree of protection
Safety instructions
• Installation of this device may only be carried out by specialist staff who have
provided proof of their skills.
Antenna is located on the top of the device.
Die Antenne befindet sich auf der Geräteoberseite.
• The power supply must be switched off before handling the device.
L'antenne se trouve sur le dessus de l'appareil.
• The relevant safety and accident prevention regulations must be observed.
L'antenna si trova sul lato superiore.
La antena se encuentra en la parte superior del aparato.
Antennen sitter på enhetens ovansida.
Das basicDIM Wireless PWM CV 4CH Modul ist ein über Bluetooth steuer-
D
barer, Vierkanal-PWM-Dimmer für Konstantspannungs LED-Lasten, wie z.B.
LED-Streifen und Konstantspannungs LED-Module. basicDIM Wireless PWM
CV 4CH Modul wird mit 12–24 V DC versorgt.
An den Ausgang wird die LED-Last angeschlossen.
Technische Daten
Spannungsbereich DC (Ein- / Ausgänge)
Max. Eingangsstrom
Max. Ausgangsstrom
Ausgangsleistung
Typ. Leistungsaufnahme im Stand-by
Betriebsfrequenz Funkempfänger
Max. Ausgangsleistung Funkempfänger
Umgebungstemperatur
tc-Punkt
Lagertemperatur
Abmessungen L x B x H
Schutzart
Sicherheitshinweise
• Die Installation dieses Geräts darf nur von fachkundigen Personen, die einen
Nachweis über ihre Qualifikation vorgelegt haben, durchgeführt werden.
• Vor dem Arbeiten am Gerät muss die Stromversorgung ausgeschaltet werden.
• Die geltenden Sicherheits- und Unfallverhütungsvorschriften sind zu beachten.
basicDIM Wireless PWM CV 4CH
Installation Instructions
Ensure that the mains voltage is switched off when you are establishing
connections. Use single or multiple-stranded cable with a cross-section of
0.75–1.5 mm².
Remove 6–7 mm of insulation at the end of the cable.
Insert the cables in the intended openings and tighten the screw terminal.
Ensure that the inputs and outputs are connected correctly.
12–24 V
The input terminals (Input) are labelled with the „+" and „–" icons, and the output
6 A
terminals (Output) are labelled with „+" and „–(1)", „–(2)", „–(3)", „–(4)".
6 A
144 W / 24 V DC, 72 W / 12 V DC
Compatible devices
< 0.3 W
Compatible with all Android 4.4 (KitKat) or later, iPhone 4S (iOS 5.0) or later and
2.4–2.483 GHz
iPAD 3 (iOS 5.1) or later.
+ 4 dBM
-20... +45 °C
Hereby, Tridonic declares that the radio equipment type basicDIM Wireless PWM
75°C
CV 4CH is in compliance with Directive 2014/53/EU.
-25... +75°C
72.6 x 30.0 x 18.0 mm
Hereby, Tridonic declares that the radio equipment type basicDIM Wireless PWM
IP20
CV 4CH is in compliance with Directive UK SI 2017 No. 1206.
The full text is available at the following internet address:
https://trid.help/en28002575cer
Areas of application
The device may only
• be used for the applications specified.
• for safe installation in dry, clean environment.
• be installed in such a way that access is only possible using a tool.
Installationshinweise
Achten Sie darauf, dass die Netzspannung abgeschaltet ist, wenn Sie Verbindungen
herstellen. Verwenden Sie eindrähtige- oder mehrdrähtige Kabel mit einem
Querschnitt von 0,75–1,5 mm². Isolieren Sie am Kabelende 6–7 mm ab.
Stecken Sie die Kabel in die dafür vorgesehenen Öffnungen und ziehen Sie die
Schraubklemme an.
Stellen Sie sicher, dass Ein-und Ausgänge korrekt angeschlossen werden.
Die Eingangsklemmen (Input) sind mit den Symbolen „+" und „–" gekenn-
12 – 24 V
zeichnet, die Ausgangsklemmen (Output) sind mit „+" und
6 A
„–(1)", „–(2)", „–(3)", „–(4)" gekennzeichnet.
6 A
Kompatible Geräte
144 W / 24 V DC, 72 W / 12 V DC
< 0,3 W
Kompatibel mit Android 4.4 (KitKat) oder höher, iPhone 4S (iOS 5.0) oder höher
2,4 – 2,483 GHz
und iPAD 3 (iOS 5.1) oder höher.
+ 4 dBM
-20 ... +45 °C
Hiermit erklärt Tridonic, dass der Funkanlagentyp basicDIM Wireless PWM CV 4CH
75 °C
der Richtlinie 2014/53/EU entspricht.
-25 ... +75 °C
72,6 x 30,0 x 18,0 mm
Hiermit erklärt Tridonic, dass der Funkanlagentyp basicDIM Wireless PWM CV 4CH
IP20
der Richtlinie UK SI 2017 No. 1206 entspricht.
Der vollständige Text ist unter der folgenden Internetadresse verfügbar:
https://trid.help/en28002575cer
Einsatzbereich
Das Gerät
• darf nur für den bestimmungsgemäßen Einsatz verwendet werden.
• muss für eine sichere Installation in einer trockenen, sauberen Umgebung
installiert werden.
• muss so installiert werden, dass der Zugang nur mit einem Werkzeug möglich
ist.
article number/Artikelnummer: 28002575

Publicidad

loading