6. TROUBLESHOOTING
Problem
Possible causes
The water tank is full,
and the indicator light is
1. The appliance does
flashing.
not switch on when
The room temperature is
pressing the on/off
higher than the selected
button
temperature (in heat
mode).
The room temperature is
lower than the selected
temperature (in cool
mode).
There is a window or a
2. It does not cool enough
door open.
There is a heat source
inside the room.
The exhaust hose is not
properly positioned or is
blocked.
The temperature is too
high.
The air outlet is blocked.
The floor is not level or
3. The appliance makes
not flat enough.
noise
The sound comes from
the airflow inside the
appliance.
78
FORCECLIMA 7150 STYLE / FORCECLIMA 7550 STYLE CONNECTED/ FORCECLIMA 9150 STYLE
FORCECLIMA 9450 STYLE HEATING / FORCECLIMA 9550 STYLE HEATING CONNECTED/ FORCECLIMA 12650 STYLE HEATING
FORCECLIMA 12850 STYLE HEATING CONNECTED
Possible solutions
Empty the water tank.
Adjust the temperature.
Adjust the temperature.
Make sure that all windows and
doors are properly closed.
If possible, remove the heat
source from the room.
Fit it properly or clean it.
Adjust the temperature.
Clean it.
If possible, place the device on a
flat and level floor.
This is normal.
4. E0 Code
Room temperature sensor
fault.
5. E1 Code
Condenser temperature
sensor fault.
6. E2 Code
The water tank is full
when the cool mode is in
operation.
7. E3 Code
Evaporator temperature
sensor fault.
8. E4 Code
The water tank is full
when the heat mode is in
operation.
1. Service information
1.1 Area verification
Before starting work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimised. Before repairing the cooling system,
the following precautions must be observed:
1.2. Work procedure
The work must be carried out in accordance with a controlled procedure to minimise the risk of
a flammable vapour or gas being present while the work is being carried out.
1.3. General workspace
All maintenance personnel and others working in the area should be briefed on the nature
of the work to be carried out. Work in confined spaces must be avoided. The area around the
workspace should be divided into sections. Ensure that conditions within the workspace are
safe by keeping flammable material under control.
1.4. Refrigerant verification
The area should be checked with an appropriate refrigerant detector before and during
work to ensure that the technician is warned of potentially flammable atmospheres. Ensure
that the leak-detection equipment used is suitable for use with flammable refrigerants, i.e.
non-sparking, adequately sealed, or intrinsically safe.
FORCECLIMA 7150 STYLE / FORCECLIMA 7550 STYLE CONNECTED/ FORCECLIMA 9150 STYLE
FORCECLIMA 9450 STYLE HEATING / FORCECLIMA 9550 STYLE HEATING CONNECTED/ FORCECLIMA 12650 STYLE HEATING
ENGLISH
Change the sensor (the
appliance can be used without
this sensor).
Change the sensor.
Remove the rubber cap and
drain the water.
Change the sensor.
Empty the water.
79
FORCECLIMA 12850 STYLE HEATING CONNECTED

Publicidad