To clean the exterior finish, use a damp, sudsy cloth. For stubborn
stains, a non-abrasive liquid cleanser or spray glass cleanser could
be used.
TROUBLESHOOTING
Errors
1.
Meaning: Temperature sensor short circuit
Possible causes:
a) Sensor short-circuited internally.
b) Sensor wires in the PCB board is short-circuited.
Solutions:
a) Replace the sensor – contact customer service for assistance if
still under warranty.
b) Replace the PCB – contact customer service for assistance if still
under warranty.
2.
Definition: Temperature sensor open circuit
Possible causes:
a) The sensor plug is loose.