How to measure DC V voltage
1. Never measure a voltage exceeding 500V, although it is possible to obtain a reading of the value. This
operation could damage the internal circuit and create danger for the user.
2. When the voltage to be measured is unknown, set the knob to the maximum range. Then rotate it to
a lower value as needed until you get a satisfactory reading.
3. If the display shows "1", it means that the selected range is overloaded and it is therefore necessary
to set a higher range.
How to measure AC voltage V
1. Never measure a voltage exceeding 500V, although it is possible to obtain a reading of the value. This
operation could damage the internal circuit and create danger for the user.
2. When the voltage to be measured is unknown, set the knob to the maximum range. Then rotate it to
a lower value as needed until you get a satisfactory reading.
3. If the display shows "1", it means that the selected range is overloaded and it is therefore necessary
to set a higher range.
How to measure DC current TO
Up to 200mA
From 200mA to 10°
1. Do not perform the measurement when the value between the open-circuit voltage and earth
exceeds the safety voltage 60V: This could damage the device being measured or the instrument and
create danger for the user.
2. Before measurement, disconnect the power from the device under test and check that the input
terminal or knob is set to the correct range, and then turn on the power to the device under
measurement.
3. When the magnitude of the current to be measured is unknown, set the knob to the maximum range.
Then rotate it to a lower value as needed until you get a satisfactory reading.