COMPACT 1.4
• Repair possible obstruction of the centrifugal blower or condenser fan; If the error persists,
replace the centrifugal blower or condenser fan (to access the blower or fan it is necessary to
remove the outer cover of the device, and the evaporator cover for the centrifugal blower).
• Replace fuse 24V - 7,5A / 12V - 10A. To access the fuses of the centrifugal blower or
condenser fan you must remove the internal air distribution panel.
• Replace electronic board.
!
(If the error persists contact an Authorised Service Centre).
• Connect terminals of the control module correctly. (According to electrical diagram attached).
• Replace electronic module/s on the compressor/s.
• Replace compressor/s.
• Check pressure (from 6 bars the compressors switch off), if necessary recover gas and reload
250 grams per circuit.
!
To access compressors, electronic modules of compressor or charging jacks you must
remove the device's outer cover.
!
(If the error persists contact an Authorised Service Centre).
• Reprogramme the remote control.
• Replace the remote control's battery and reprogramme.
• Replace electronic control.
• Replace the remote control.
!
(If the error persists contact an Authorised Service Centre).