Fault: Electronic unit overheating.
Solution: Shutdown of the electronic unit due to overheating, in cases of high temperatures or overloaded
system. Check whether the electrical installation, fuse holder or fuse are faulty. Also check if the
E5
refrigerator is in an environment that has ventilation, without blockages that interfere with the passage
of air to the electronic unit and compressor.
Fault: Electronic unit failure.
E6
Solution: Replace the electronic unit.
Fault: Compressor was turned off because the refrigerator is tilted above 25°.
Solution: It will start working again when the inclination is less than 25° and after counting from 99 to 0
to
(totaling 5 minutes), the time necessary for the refrigeration system to stabilize.
Fault: Temperature sensor harness broken or disconnected. The compressor will remain on until the
problem is resolved.
OP
Solution: Take it to authorized technical assistance to identify the problem.
Fault: Shorted temperature sensor harness or defective sensor. The compressor will remain on until the
problem is resolved.
SH
Take it to authorized technical assistance to identify the problem.