Troubleshooting
Fault
The connected devices
are not being supplied
with power.
All LEDs red, flashing
 Declaration of Conformity
This is to certify that the product Instagrid LINK
of the manufacturer Instagrid GmbH complies
with the requirements of the applicable direc-
Licenses and copyrights
All intellectual property (IP), including but not limited to copyrights, patents, designs, trademarks and
trade secrets, in all products, parts, accessories, user manuals and packaging is the property of Instag-
rid GmbH. Instagrid® is a registered trademark of Instagrid GmbH. All names, logos and indications of
commercial origin that are not registered trademarks are unregistered trademarks of Instagrid GmbH.
Possible cause
The overload protection has
been tripped
Residual current circuit brea-
ker has tripped.
Connected consumer
defective.
Instagrid LINK defective.
Correction
Ensure that the total current consump-
tion of all loads does not exceed 16
A. Set the circuit breaker to the swit-
ched-on state.
Have all consumers, their supply lines,
any other cables used and the Instagrid
LINK checked by a qualified electrician.
Do not continue to operate the system.
Contact the manufacturer of the applian-
ce or a qualified electrician.
Contact the Instagrid service
tives, including all applicable amendments. The
complete declaration of conformity can be found
at: https:/ /www.instagrid.co.