INSTALLATION AND WIRING
• Installation of electric equipment must be carried out
by qualified professionals.
• Before you start making any connections, disconnect
the power supply to avoid any risk.
• When some kinds of lamps blow, they can produce a
very high current which could damage the detector.
NOTE
Once the detector is connected to the power supply, it is
necessary to wait 30 seconds for it to stabilize. During this
time, the device activates its output and does not respond to
movement.
● Follow one of the following diagrams to make the connection:
- Simple installation of a single detector:
230V~
50/60Hz
- Installation of two detectors in parallel with a single charge:
230V~
50/60Hz
- Installation with Normally Closed Pushbutton to perform
manual ignition during 30 seconds. With each press (> 1s) the
device will activate charging during 30 seconds, after which it
will switch to automatic operation depending on the detection:
230V~
50/60Hz
SETTINGS
● ALL OPERATION SETTINGS OF THIS DETECTOR ARE
EXCLUSIVELY CONFIGURED THROUGH THE DINUY
CONFIGURE APP (see below).
● To consult about the installation of the App, menus, application of
the configuration, or the resolution of problems related to the
configuration, please consult the instructions for use of the DINUY
CONFIGURE App.
● The basic operating values of this detector are 'Timing', 'Brightness´
and 'Sensitivity' can be adjusted using the DINUY CONFIGURE
App.
- Timing Setting (TIME)
Factory setting: 1 minute.
Sets the time the charge will be on after detecting movement.
The ignition time can be adjusted between 1sec. and 60min.
After the first detection, the time will be reset and, each time a
new movement is detected, the timing will begin again.
- Brightness Adjustment (LUX)
Factory setting: Disabled.
Its function is to set the maximum luminosity value, above
which the detector will not activate the load despite detecting
movement. Furthermore, in mode Presence Detector if the set
brightness level is exceeded while the lighting is activated
(presence of people), the load will be automatically deactivated.
The user can set this value depending on their requirements,
between 5 and 2.000 Lux and disabled.
If this parameter is set to a very low value, close to 5 Lux, the
detector will only work in the dark, at night (in case there is not
enough natural light).
If this parameter is set to the value Disabled, the detector will
work in any light level, regardless of natural light, both day and
night.
- Sensitivity Adjustment
Factory setting: Very High.
This parameter allows you to limit the detection range and
adapt the operation to, for example, unstable environments.
You can choose between 5 adjustment options:
• Very High
• High
• Medium
• Low
• Very low
FUNCTION TEST
● The purpose of this test is to check and adjust the coverage area of
the detector when it is first connected.
NOTE
Once the detector is connected to the power supply, it is
necessary to wait 30 seconds for it to stabilize. From that
moment, the operation test can be carried out.
● The red LED visually indicates when motion is detected and works
both when the load is on and off.
● This red LED will light up whenever motion is detected.
● Walk from outside the coverage area inward until the lights turn on.
● The blue LED indicates that the Bluetooth is activated and ready to
receive the programming from the smartphone. Once the detector is
powered at 230V~ the Bluetooth will be activated for a while. After
this time the Bluetooth will be automatically deactivated. This time
can be selected from 10 minutes to 4 hours. The factory setting is
2 hours.
● Once you have verified that the operation is correct, save the
detector settings with the desired values
LIMITING CAP
● A limiting cover is included in the same detector box, which allows
you to exclude areas from the detection area, as well as reduce the
coverage area according to needs.
● In the event that the default detection area of the detector is too
large, or it is detected in areas that are not desired, this area can be
easily reduced simply by using the shutter covers.
PROBLEM RESOLUTION
When the detector stops working normally, review the possible faults
and the suggested solutions in the following table that will help you
solve the problem:
Problem
The lamps do
not turn on
The lamps
don't go out
Lamps turn
on and off
cyclically
Unwanted
activations
Lamps work
in reverse,
turning on
when they
should
be off,
and off
when they
should be on
ATTENTION: Dangerous voltage!.
L
N
L
N
N L
L
N
Possible cause
No voltage
reaching
the detector
Bad connection
Poorly adjusted LUX
Defective charge
Very high
ambient
temperature
The set
shutdown time
is too long
The detector
trips
unexpectedly
Bad connection
The load
(fluorescence,
contactor...)
is generating
harmonics
that continuously
trigger
the detector
with each
switching
Heat sources,
drafts, reflective
surfaces
or objects
that move
due to wind
The Output
Polarity is
set in reverse
Load
N L
L
L
Load
L
L
N L
Load
N L
L
L
L
L
Suggested Solution
Properly power
the detector
Check the
connections and
follow the
instructions
diagram
Check Brightness
Adjustment setting
Replace the load
Wait for the ambient
temperature to
reduce and test
the detector
Reduce
disconnection time
and check that
the lamps turn off
after the time
has elapsed
Stay out
of the coverage
area to avoid
false activations
Make sure
the charging
and power
are connected well
Move the
detector away
from the load
or place an
RC harmonic
suppression
filter (AC DM-002)
between
L' and N
Avoid directing
the detector
towards heat
sources, such as
air conditioners,
fans, radiators.
Make sure there
are no objects
that move
with the wind.
Reduce
the Sensitivity
of the detector
with the
APP Dinuy
Configure.
Make sure you
change the
Output Polarity
in the
ADVANCED MENU