• For products with 5-pin M12 plug, use a 6-pin cable with separate analog
ground as an alternative (available as an accessory).
only with
0 / 4 ... 20 mA
GND
Inductive load
GND
Fig. 3: Electrical connection with 5-pin M12 plug
6.6.4 Connection with 8-pin M12 plug
Notes
• The maximum current for the digital output is 200 mA (PNP output).
AVENTICS™ Sentronic 625 | IM502079-014-R01 | English
Control
+24 V DC (supply voltage)
0 V DC (supply voltage)
GND
Analog input (set point)
0 ... 10 V
(or 0 / 4 ... 20 mA)
Set point mass
(only with 6 wire cable)
Analog output (actual value)
max.
0 ... 10 V
500 Ω
(or 0 / 4 ... 20 mA)
Set point mass
Digital output
(pressure switch)
max. 200 mA / 4.8 W
Shield
FE
Procedure
Connect the product according to the pin assignment. See
u
rameters.
M12 plug, 5-pin.
M12 electrical
connector of the cable
Shield
Housing M12 electrical
connector
• The digital output is protected against short circuits and overloads.
Procedure
Connect the product according to the pin assignment. See
u
rameters.
1
M12 flange plug of the
2
valve
1
3
250 Ω with
2
set point 0 / 4 ... 20 mA
4
5
Housing M12 flange plug
M4 connection valve housing
g 11. Data and pa-
4
5
3
g 11. Data and pa-
20