Disconnect main vehicle power before connecting 12 volt DC power to the
fan.
STEP 5
• If the roof/wall is thicker than 1 inch the extension
sleeve must be used.
• A roof/wall that is 6 inches thick will use the full-length
extension sleeve without trimming.
VEHICLE
ROOF/WALL
THICKNESS
6.0
1.0 inch
• If the roof/wall is between 1 inch and 6 inches, the
extension sleeve may need to be trimmed.
• Measure the distance from the vehicle ceiling/wall to
the base of the MAXXFAN Dome fan. Cut the
extension sleeve longer than the dimension measured
to accommodate the depth of the garnish ring. Refer to
table below for additional length required.
NOTE: Mark and cut the extension sleeve per figure 5
shown above.
VEHICLE
ROOF/WALL
THICKNESS
1 1/8 to 5 7/8 inch
STEP 6 Non-LED MAXXFAN Dome
Using the supplied wire splices, connect the Positive (+)
12VDC supply wire to the MAXXFAN Dome fan wire
marked "POS 12VDC" and the Negative (-) 12VDC supply
wire to the MAXXFAN Dome fan wire marked "Neg.
12VDC".
If the sleeve is needed, insert the sleeve into the
garnish ring positioning the notch in the sleeve to line
up with the wiring.
Raise the garnish ring to the ceiling/wall ensuring
that the garnish ring is centered over the fan
opening.
If using the sleeve, the sleeve will overlap the base
that extends in the opening. This will help center the
garnish ring in the opening.
Ensure that the wires are not pinched. The wires
should be routed on the outside of the sleeve. The
SLEEVE LENGTH TO CUTOFF
LED
NONE (use full
NONE (use full
length sleeve)
length sleeve)
Not Applicable,
Not Applicable,
Sleeve not
used
LENGTH TO ADD TO
CEILING/WALL THICKNESS
MEASUREMENT
LED
15/16 inch
CAUTION!
NON-LED
Sleeve not
used
NON-LED
1/2 inch
MAXXFAN Dome exhaust