Important:
Ensure that the incoming power supply
voltage matches the setting of the
voltage selector switch!!!!!!
The voltage selector switch is located behind
the top brick panel on the right hand corner.
When wiring the unit for 208/240 volts the
voltage selector switch should be in the
Section 3: Voltage Selector Switch Location
Voltage Selector Switch: Figure 2
Caution:
When changing the voltage selector switch
from 240 volts to 120 volts ensure that the
power supply is turned off.
230 volt position. (see figure 2)
When wiring the unit for 120 volts the voltage
selector switch should be in the 115 volt
position. (see figure 2)
E-5
230
115