6. Electrical work
Fig. 6-14
Fig. 6-16
Fig. 6-15
B
Fig. 6-17
6.3.2. By wireless remote controller
1 Going to the function select mode
Press the
button between of 5 seconds.
(Start this operation from the status of remote controller display turned off.)
[CHECK] is lighted and "00" blinks. (Fig. 6-14)
Press the
button to set the "50".
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
A
2 Setting the unit number
Press the
button to set unit number A. (Fig. 6-15)
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
3 Select a mode
Press the
button to set Mode number B. (Fig. 6-16)
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
Current setting number:
4 Selecting the setting number
Use the
button to change the Setting number C. (Fig. 6-17)
Direct the wireless remote controller toward the receiver of the indoor unit and
press the
button.
5 To select multiple functions continuously
Repeat select 3 and 4 to change multiple function settings continuously.
6 Complete function selection
C
Direct the wireless remote controller toward the sensor of the indoor unit and
press the
Note:
Make the above settings on units as necessary.
• Table 1 summarizes the setting options for each mode number.
• Be sure to write down the settings for all functions if any of the initial settings
has been changed after the completion of installation work.
1=1 beep (1 second)
2=2 beep (1 second each)
3=3 beep (1 second each)
button.