PROGRAM THE DISPLAY
1. Open the RedVision
Configurator App.
®
2. From the Choose System screen, tap Open Configuration
3. From the Choose Configuration screen, tap the configuration
you want to use to Program the Display. The configuration menu
will appear.
4. Tap Program
then choose your system from the list. The App
will connect to the Display and the programming process will
begin.
The process takes approximately 1 to 2 minutes to complete
— DO NOT close the App or use other Apps or functions
on your Smartphone while your RedVision
programmed.
5. When programming is complete, your smartphone will display
a confirmation message, and the Display will show the new
configuration.
Failed to Program: If the Programming process fails, repeat the
steps again before contacting REDARC. If it continues to fail,
contact REDARC directly, or your local REDARC Distributor.
SYSTEM TESTING
1. Download and install the RedVision
2. Open the App and check that each connected device appears
and functions as intended. This can be confirmed via the
RedVision Display, however also testing the install using the
RedVision App is strongly recommended.
3. Make sure the device labels and icons are easy to understand.
GET THE REDVISION
APP
®
Monitor and control your RedVision
via Bluetooth
.
®
The RedVision
the TVMS Rogue have not been tested on all
smartphone models. Visit the application pages
within your App store for compatibility details.
CARE AND MAINTENANCE
Do not use solvents, alcohol, or domestic cleaning products to
clean the TVMS Rogue. If sand, grit, or dirt accumulate on the
Main Unit, wipe it clean with a slightly damp cloth.
Do not allow the TVMS Rogue to come into contact with
corrosive substances.
Periodically check that all connections are firm, and that all
cables are adequately managed. Parts of the system may have
moved as a result of repeated vibration, particularly if the vehicle
has been travelling on uneven/corrugated road surfaces.
system is being
®
App.
®
®
System using your smartphone
®
App and its interactions with
TROUBLESHOOTING
.
FAULTS
Faults are indicated by the Status LED on the Main
Unit:
Flashing red — Communications Fault
Solid red — Output Fault
Communications Fault Resolution
To resolve a communications error, complete the following steps,
in order, before directly contacting REDARC or your local REDARC
Distributor.
1. Check all CAN Bus (RJ45) cables to make sure they are securely
connected to the correct connector interface on each RedVision
CAN Bus device in your system.
2. Confirm that terminating resistors are fitted at each end of the
CAN Bus 'chain'.
Output Fault Resolution
In the event of an Output Fault refer to the RedVision
RedVision
App to identify the cause of the Fault.
®
LIMITED WARRANTY
For full warranty terms and conditions, visit the Warranty page of the
REDARC website: www.redarcelectronics.com/warranty
Australia, New Zealand & Europe
REDARC Electronics Pty Ltd, 23 Brodie Road (North), Lonsdale SA
5160, Australia
Australia
+61 8 8322 4848
New Zealand
+64 9 222 1024
UK & Europe
+44 (0)20 3930 8109
North America
REDARC Corporation, c/o Shallco, Inc., 308 Component Dr.
Smithfield, NC 27577, USA
USA
+1 (704) 247 5150
Canada
+1 (604) 260 5512
Mexico
+52 (558) 526 2898
IMPORTER CONTACT INFORMATION
For written request please email power@redarcelectronics.eu
UK
Ozparts UK Ltd, 1 Prospect Place, Pride Park, DE24 8HG, Derby, UK
Europe
Ozparts Pl sp. z o. o., ul. Slowackiego 32/5, 87−100 Torun, Poland
EN
®
Display or the
®
9